Cap
DC Sensor
Connector
Screw
Install the DC Sensor
NOTICE: Do not pinch or kink the wires between the cap and the
valve body. If the wires are damaged, the unit may not operate.
Hold the cap vertically with the sensing holes down and align the
DC sensor with the cap.
Slide the DC sensor into the cap until the sensor eye aligns with
the hole in the cap. Ensure the sensor wires are not pinched.
Place the sensor strap over the DC sensor and tighten the screws
in the cap until snug.
Connect the DC sensor connector to the solenoid connector on the
valve. Ensure that the connector pair is fully seated.
Locate the connector assembly adjacent to the battery to prevent
pinching when the cap is reinstalled on the valve.
Place the cap on the valve body.
Secure the cap with the setscrew.
Verify that the valve functions correctly.
Kohler Co.
Setscrew
DC Sensor
Sensor Strap
11
1108709-5-E