Plug In Receiver; External Aerial; Control Panel - V2 GOLD400D Manual Del Usuario

Ocultar thumbs Ver también para GOLD400D:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

• Timer mode: it is similar to the standard mode but the gate
stays open (completely or partially) while the contact is closed
on input; as soon as the contact is open the pause time count
down will start, after which the gate will be closed again.
This function allows programming the gate opening time
during the day, by making use of an external timer.
Automatic closing must be enabled.
In all modes, inputs must be connected to devices having
normally open contacts.
Connect cables of device controlling the first input between
terminals 1 and 4 of the control unit.
Connect cables of device controlling the second input between
terminals 2 and 4 of the control unit.
The first input function can also be activated by pressing UP key
outside the programming menu or by means of a remote control
stored on channel 1 (see relevant instructions of MR1 receiver).
The second input function can also be activated by pressing
DOWN key outside the programming menu or by means of a
remote control stored on channel 2.

PLUG IN RECEIVER

Pd8 control unit is suitable for plugging in a Personal Pass MR1
receiver having a high-sensitivity super-heterodyne architecture.
m
WARNING: it is necessary to turn off the control unit
power before doing the operations mentioned here below.
Pay attention to the way you connect the removable
modules.
MR1 module receiver is provided with 4 channels and each of
them is suitable for a command of Pd8 control unit:
CHANNEL 1
START
CHANNEL 2
PEDESTRIAN START
CHANNEL 3
STOP
CHANNEL 4
FOR FUTURE USES
m
WARNING: Before programming 4 channels and
function logics read carefully the instructions of MR1.

EXTERNAL AERIAL

We suggest to use the external aerial (model: ANSGP433) in
order to guarantee the maximal range.
Connect the antenna hot pole to terminal 20 of the control unit
and the braiding to terminal 21.

CONTROL PANEL

When power is on, the control unit checks that display correctly
operates by switching on all segments for 1.5 sec. 8.8.8.8.
Firmware version, e.g. Pr I.9, will be viewed in the following
1.5 sec. Panel will be viewed upon completion of this test.
The control panel represents the physical status of the
terminal board contacts and of the program mode keys: if the
upper vertical segment is on, the contact is closed; if the lower
vertical segment is on, the contact is open (the above picture
shows an instance where the inputs START, START P, FOTO 1,
FOTO 2,COSTA 1, COSTA 2 and STOP have all been correctly
connected).
Points being among display digits show the status of
programming push-buttons: as soon as a push-button is pressed,
its relevant point turns on.
The arrows on the display left side show the status of the ends
of stroke. The arrows go on when the related limit sensor
indicates that the gate is completely closed or open.
The arrows on the display right side show the gate status:
• The highest arrow turns on when the gate is into its opening
phase. If it blinks, it means that the opening has been
caused by a safety device (border or obstacle detector).
• The central arrow shows that the gate is on pause. If it
blinks, it means that the time countdown for the automatic
closing has been activated.
• The lowest arrow blinks when the gate is into its closing
phase. If it blinks, it means that the closing has been
caused by a safety device (border or obstacle detector).
33

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Gold800dGold1200d

Tabla de contenido