Opening control for the connection of control
1
devices with N.O. contact
Opening controls for pedestrian access for the
2
connection of control devices with N.O. contact
3
Stop command. N.C. contact
4
Common (-)
5
Photocells type 1. N.C. contact
6
Photocells type 2. N.C. contact
7
Safety ribbons type 1 (fixed). N.C. contact
8
Safety ribbons type 2 (mobile). N.C. contact
9
Common (-)
Power output 24 VAC for photocells and other
10 - 11
accessories
11 - 12
Photocell TX power supply for functional test
Flashing light
13 - 14
230VAC 40W (Pd8) / 120VAC 40W (Pd8-120V)
15 - 16 -
Motor
17
ELECTRIC CONNECTIONS TABLE
48
18
Neutral 230 VAC / 120VAC
19
Power phase 230 VAC / 120VAC
20
Antenna
21
Antenna shield
22 - 23 -
Limit sensor
24 - 25
26 - 27
Capacitor
F1
5A (Pd8) / 8A (Pd8-120V)
MAINS
It shows that the control unit is power supplied
It shows that there is an overload on accessories
OVERLOAD
power supply
FCC
It shows the opening end of stroke activation
FCA
It shows the closing end of stroke activation
OPEN
Opening in progress
PAUSE
Pause (gate opened)
CLOSE
Closing in progress