INSTALLING THE MAGNETIC
LIMIT SWITCHES
Install the supplied magnet holder on the rack in a way that, in
the opening and closing limit positions, the magnet be
positioned next to the magnetic sensor behind the hood (as near
as possible to the hood).
The supplied magnets have been colored differently in order to
be distinguished from each other:
BLUE MAGNET = RIGHT LIMIT SWITCH (DX)
RED MAGNET = LEFT LIMIT SWITCH (SX)
The type of limit switch (RIGHT/LEFT) depends on the position of
the limit switch towards the motor, independently from the
opening sense.
INSTALLING THE MECHANICAL LIMIT SWITCHES
Install limit switches on the rack and fix them using the screws provided in the tool kit.
m
ATTENTION: check that the limit switch bracket will work effectively on the limit switch spring of the motor.
If necessary add thickness between the lower part of the rack and the limit switch bracket in order to keep to the
measurement as stated in the figure.