The Picture below indicates the external equipotential bonding system.
It must be used to guarantee that there is no potential difference between all the appliances
connected to the power grid, diminishing risks of electrical shock.
The different appliances must be turned on one to the other using their respective
equipotential bonding system.
Switch and Eletric cables dimensions
1 - The switches must be exclusive to the appliance
2 - The wires dimensioning listed in the table below is for maximum length of 25 meters.
3 - The grounding is mandatory.
Model
Maxiconv Oven
Water Points Connection
1 - The ovens must be connected to a cold water pipeline.
2 - Before turning on the hydraulic part, unload the water conductors of the building to
remove possible durt from the pipe.
3 - It is necessary to provide a ¾ screw for the meter to connect the hose to the water
entrance.
4 - Before turning on the hydraulic hose it is necessary to check the water exit according to
the recommendation of the table below.
5 - The new hose sets provided with appliance must be used and the old sets of hoses must
not be reused.
10
45006.5
Switch and cables dimensions table
Switch
25 A
220 mono/biphasic
Gauge wire
2,5 mm²