Appendix
Appendix 1
State
Low voltage alarm
SpO2 alarm
Pulse rate alarm
Probe error alarm
Appendix 2
Guidance and manufacture's declaration – electromagnetic emissions-
Guidance and manufacture's declaration – electromagnetic emission
The Pulse Oximeter is intended for use in the electromagnetic environment specified below. The
customer of the user of the Pulse Oximeter should assure that it is used in such and environment.
Emission test
RF emissions
CISPR 11
RF emission
CISPR 11
Harmonic emissions
IEC 61000-3-2
Voltage
fluctuationsflicker
emissions
IEC 61000-3-3
Guidance and manufacture's declaration – electromagnetic immunity –
Guidance and manufacture's declaration – electromagnetic immunity
The Pulse Oximeter is intended for use in the electromagnetic environment specified below. The
customer or the user of Pulse Oximeter should assure that it is used in such an environment.
Immunity test
Electrostatic discharge
(ESD)
IEC 61000-4-2
Power frequency
(50/60Hz) magnetic
field
IEC 61000-4-8
Guidance and manufacture's declaration – electromagnetic immunity –
for EQUIPMENT and SYSTEMS that are not LIFE-SUPPORTING
Guidance and manufacture's declaration – electromagnetic immunity
The Pulse Oximeter is intended for use in the electromagnetic environment specified below. The
customer or the user of Pulse Oximeter should assure that it is used in such an environment.
IEC 60601 test
Immunity test
level
Alarm condition delay
0.6s
400ms
400ms
400ms
Guidance and manufacture's declaration
for all EQUIPMENT and SYSTEMS
Compliance
Electromagnetic environment – guidance
The Pulse Oximeter uses RF energy only for its internal function.
Group 1
Therefore, its RF emissions are very low and are not likely to
cause any interference in nearby electronic equipment.
Class B
The Pulse Oximeter is suitable for use in all establishments,
Not applicable
including domestic establishments and those directly connected
to the public low-voltage power supply network that supplies
buildings used for domestic purposes.
Not applicable
for all EQUIPMENT and SYSTEMS
IEC 60601 test level
6 kV contact
8 kV air
3A/m
Compliance
level
Alarm signal generation delay
20ms
20ms
20ms
20ms
Compliance
Electromagnetic environment - guidance
level
6 kV contact
Floors should be wood, concrete or
6 kV air
ceramic tile. If floor are covered with
synthetic material, the relative humidity
should be at least 30%. The manufacturer
may recommend the ESD precautionary
procedures to user.
3A/m
Power frequency magnetic fields should be
at levels characteristic of a typical location
in a typical commercial or hospital
environment.
Electromagnetic environment - guidance