Fault
Powder is introduced
unilaterally
Tab. 14
Troubleshooting
11 Disposal
Tungsten (tungsten electrode)
Tab. 15
Critical raw materials
BAL.0086 • 2020-12-17
Cause
• Powder nozzle bore partly
clogged
• Powder gas volumetric flow too
strong or too weak
Equipment marked with this symbol is covered by European Directive
2012/19/EU on waste electrical and electronic equipment (WEEE).
• Electrical and electronic equipment must not be disposed of with
household waste.
• Electrical and electronic equipment must be collected separately and
recycled in an environmentally friendly manner.
• Please observe the local regulations, laws, provisions, standards and
guidelines.
• Your local authority can provide you with information about the collection
and return of electrical and electronic equipment.
• To dispose of the product correctly, it must first be disassembled.
11 Disposal
Troubleshooting
• Clean powder nozzle and
replace it if necessary
• Adjust powder gas volumetric
flow setting