4. Installation on Emerson Fans Having
Two-Piece Die-Cast Switch Housing (continued)
4.4
Thread the Light Fixture Assembly White and Black
Wires through the Switch Housing Cover, Lockwasher,
and Hex Nut, secure by using a wrench (Figure 15).
4.5
Connect the Ceiling Fan White Wire to the Light Fixture
Assembly White Wire using one of the previously
removed Wire Connectors (Figure 16).
Connect the Ceiling Fan Blue Wire to the Light Fixture
Assembly Black Wire using one of the previously
removed Wire Connectors (Figure 16).
WARNING
!
To avoid possible fire or electrical shock, make
certain no bare wire strands are exposed outside wire
connectors.
Figure 15
SWITCH
HOUSING
SWITCH
HOUSING
BLUE WIRE
LIGHT FIXTURE
ASSEMBLY BLACK
WIRE
LIGHT FIXTURE
ASSEMBLY
Figure 16
11
SWITCH
HOUSING
WHITE WIRE
WIRE
CONNECTORS (2)
LIGHT FIXTURE
ASSEMBLY
WHITE WIRE
emersonfans.com
Please contact 1-800-654-3545 for further assistance
LK150OM U.L. Model No.: PH334