Push in the handle release button (P.5) and move the handle (P.1)to the horizontal
position, where it will lock.
Pull the hose (P.4) out of its stowage (P.2). Connect the hose to the pedestal charging
valve (21).
Position the pump between the legs, standing with both feet on the fold-down feet (P.3).
Grip the handle (P.1) with both hands and, using full steady strokes, pressurize the
pedestal to the required pressure. Do not exceed the maximum working pressure,
indicated by the leading edge of the red sector on the gauge (22).
Disconnect the hose (P.4) from the pedestal charging valve, but do not refit the Schrader
valve cap at this stage. Fit the hose in its stowage (P.2).
Push the pump plunger fully down, push in the handle release button (P.5) and move
the handle (P.1) to the vertical position, where it will lock the pump plunger in the closed
position.
Fold up both the feet (P.3).
Pressurizing from an external pressure source
WARNING!
To pressurize the pedestal from an external pressure source, proceed as follows:
Fully depress the moving column (4) and engage the safety catch (3).
Remove the Schrader valve cap (21) and connect the charging line from the pressure
source.
Turn on the pressure supply and slowly increase the pedestal pressure to the required
pressure. Do not exceed the maximum working pressure, indicated by the leading edge
of the red sector on the gauge (22).
Disconnect the charging line, but do not refit the Schrader valve cap at this stage.
This pedestal must be pressurized only with clean, dry air or
nitrogen. A pressure reducing valve must be fitted to the
pressure line between the gas cylinder and the outlet connec-
tion of the hose. The reducing valve must be screwed into the
gas cylinder outlet. The maximum pressure on the outlet side
of the reducing valve must not exceed 9.6 bar (139 psi). Do
not pressurize the pedestal beyond the maximum safe work-
ing pressure indicated by the leading edge of the red sector
on the gauge. The pedestal is fitted with a pressure relief
valve as a safeguard against over-pressurization. 
Do not attempt to adjust the pressure relief valve.