1.5 Ventilation. It is very important to renew the air string of the room. If it is necessary, an 80
mm diameter inlet for outdoor air must be taken into account for the room where the fireplace is
located, so that the smoke flow can't be blocked. You have considered other ventilation or
heating device work simultaneously: air conditioning, other air outlet devices (bath, kitchen) or
heat pumps. In all these cases, the air going out must be balanced with the air coming in.
1.6 Type of fireplace. It is a free type so it means that it must not be covered with any other
material.
1.7 Acces for cleanning and security. From inside the heart of chimney, it is possible to clean
the flue and chimney.
1.8 Fireplace assembly.
1.8.1 Wall panel assembly (2). With plugs of 10 mm and screws of M8 place the wall panel in
the place where it is going to install the chimney, bearing in mind that place it more centred to
the exit of smokes, to respected the minimum distance of 200 mm at floor since lower part of
fireplace put the wall panel at 270 mm of the floor.
(NOTE: If you will put the fireplace with his foot optional follow the instructions that are attached
at the bottom for this section)
1.8.2. Plugs characteristics.
WORK LOAD RECOMMENDED
(Quality 6.8. Concrete 250kg./cm2)
∅ of anchor
Minimum insertion (mm) H
Extraction resist Kg.
Cutter resist Kg
∅ 10
50
350
450
TECHNICAL DATES
∅ hole mm
Plug
Screw measures
Minimum hole
Fix thickness
Force of tightens
measures
mm
depth mm
max.P
Kg. X cm
10x80
M8x80
10
85
30
150
1.8.3. Fireplace's fixation (3).
1.8.4. Installation of the smokestack (4-5) .The flue connection collar is detachable. To install
it.
1.8.5. Installation of the connector of the flue pipe (6-7-8). The cover tube pipe cover is in
two pieces. First you have put the back piece (It is advisable that you put this pieces before
install the connector collar).When you have installed the connector collar, place the cover tube
pipe (frontal piece), then (if it is necessary) you can cut the flue pipe cover to measure of the
height of this room but it is important that the holes of ceiling crest (use for hot air exit) can not
cover, fitting the two pieces.
1.8.6. Installation of the ceiling crest (9). Finally, fix the ceiling crest to the roof with the plugs
and screws.
2. USER'S GUIDE
ALL LOCAL REGULATIONS, INCLUDING THE ONES ACCORDING TO THE NATIONAL OR
EUROPEAN NORMS MUST BE ACCOMPLISHED WHEN PROCEEDING TO INSTALL THE
FIREPLACE.
Warning: Do not touch any part of the fireplace when it is in use without the protection of
the heat-resistant glove.
2.1. Using for the first time. Before burning this fireplace for the first time, the fire should burn
for a minimum of 15 hours with no more than 25% of the maximum fuel load authorised by the
manufacturer (you read the instructions on the green sheet).
2.2.Control of combustion.
2.2.1. Primary air slider (10). It is in the ash pan of fireplace. To obtain the stated output and
efficiency as the table of Technical data, move the primary air slider to 6 %.
2.2.2. Gas exit slider. It is in the connector pipe tube where the tube pipe and fireplace it is
joined. The position of the totally vertical handle indicates opened way, the position of the totally
horizontal handle indicates closed way. To obtain the stated output and efficiency as the table of
Technical data, move the gas exit slider to 23%.