Troubleshooting - Rocal ALBA 60 Manual De Caracteristicas, Instalacion Y Funcionamiento

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

3. TROUBLESHOOTING

This is a table with possible anomalies, the reason and the solutions that you could follow:
FAILURE
1.
Revokes
smoke
Insufficient flue draught
2.
Excessively
dirty
glass
3. It warms little
4.
Smoke
going
out
through front door / bad
smells
The review of the chimney as well as the installation and flue pipes should be done by a
Professional
For any doubt consult your local Rocal's dealer.
REASON
Incorrect flue draught
/
Insufficient air for combustion
Incorrect flue draught
Inadequate fuel.
Air slider insufficient open
Inadequate fuel
Insufficient fuel
Incorrect air slider
Burning for the first time
Combustible or inflammable
elements in the enclosure or
surrounding
walls
appliance
A crack in the combustion
chamber
SOLUTION
Ckeck the flue draught:
- Connection
- Diametre
- Leaks
- Insufficient lenght
- Gone out on the outside
- Flue exit may be blocked
Check the flue draught entry
Check the flue draught.
Use authorized fuel
Check the air slider (open-close)
Use authorized fuels
Add fuel
Check mechanism and opening fits according to
instructions
Wait the paint cures. This could take several uses
Review insulation materials as fibregras, fireproof
wood or possible combustible elements and
of
the
replace them
To verify his airtightness and if a crack is seen,
warn the dealer or Professional.
Página 14 de 15

Publicidad

Tabla de contenido
loading