1. Unique identification code of the product type:
70006QR00, residential space heating appliance, with water, fired by wood pellets
EN 14785:2006
2. Type, batch or serial number or any other element allowing identification of the construction product as required under Art. 11(4):
RBH 150 V,
3. Intended use or uses of the construction product, in accordance with the applicable harmonised technical specification, as foreseen by the manufacturer:
Residential space heating appliance, with water, fired by wood pellets
4. Name, registered trade name or registered trademark and contact address of the manufacturer as required by Art. 11 (5):
Ravelli
Aico S.p.A.
Via Consorzio Agrario, 3/D
25032 Chiari (Bs) Italia
5. Where applicable, name and contact address of the authorised representative whose mandate covers the tasks specified in Article 12(2):
---
6. System or systems of assessment and verification of constancy of performance of the construction product as set out in Annex V:
System 3, System 4
7. In case of the declaration of performance concerning a construction product covered by a harmonised standard:
The notified laboratory TÜV Rheinland Energy GmbH (NB 2456) performed the determination of the product type on the basis of type testing
under system 3 and issued test report K27262019T1
8. Declared performances:
Harmonized technical specification:
Essential characteristics
Fire safety
Reaction to fire
Distance to combustible materials
Risk of burning fuel falling out
Emission of combustion products
(at 13% of O
)
2
Surface temperature
Electrical safety
Cleanability
Maximum operating pressure
Flue gas temperature at nominal heat output
Mechanical resistance(to carry a chimney/flue)
Nominal heat output
Room heating output
Water heating output
Efficiency
9. The performance of the product identified in points 1 and 2 is in conformity with the declared performance in point 8. This declaration of performance
is issued under the sole responsibility of the manufacturer identified in point 4.
DECLARATION OF PERFORMANCE
Declaration of performance according to Regulation (EU) 305/2011
n. : 213CPR13.07
Signed for and on behalf of the manufacturer Claudio Mezzalira, Operations Manager
Place
Chiari
EN 14785:2006
Performance
A1
Minimum distances (mm):
rear = 50
sides = 200
front = 800
ceiling = 50
floor = 0
Pass
Nominal heat output
CO 0,005 % - 57 mg/Nm
NOx 153 mg/Nm
OGC 1 mg/Nm
PM 14,9 mg/Nm
Reduced heat output
CO 0,011 % - 140 mg/Nm
OGC 2 mg/Nm
Pass
Pass
Pass
--
140 °C
NPD
18,1 kW
2,7 kW
15,4 kW
Ƞ 91,6 % Nominal heat output
Ƞ 93,1 % Reduced heat output
Date
21/06/2021
3
3
3
3
3
3
Sign _______________