Stove status
In this menu, you can check the correct operation of the most important parameters of the appliance. Below is a list of real stove data
useful for the assistance service during the control phases.
ACTIVE COMPONENTS
- PUMP:
circulator state (ON running)
- 3-WAY VALVE: position of 3-way valve DHW (domestic hot water) or HEAT (heating);
- PRESSURE: system pressure;
- Stove status;
REAL STATUS
- POWER: current boiler power;
- RDS: flow read by the flow meter;
- RPM: fume extractor speed;
- SET: actual flow set (Air-flow meter);
TEMPERATURES
- REMOTE CTRL TEMPERATURE: Temperature read by the handheld unit;
- T.EXT: External thermostat (request ON);
- T.FLAME: Flame temperature (combustion chamber);
- T.SMOKE: Combustion fume exhaust temperature;
- T.DEB.C: Inlet flow meter temperature;
- T.DEB.H: Heated flow meter temperature;
- T.MB: Electronic board temperature;
TEMPERATURE H20
- T.H20 O: Boiler water temperature (SUPPLY);
- T.H20 I: Boiler water temperature - RETURN from the system;
- WATER HEATER T.: Boiler DHW temperature;
- T.PUFFER H: Puffer temperature - average warm point;
- T.PUFFER L: Puffer temperature second reading (low temperature).
Comfort clima
Activating this function allows the stove to turn off automatically, once the desired room temperature has been reached. When the
room temperature reaches the value set on the palmtop or on the external thermostat, the stove activates the modulation phase. If
the temperature reached is maintained for a set period of time (DELAY SWITCH OFF), the stove switches off automatically, and the
message ECO appears on the display. The stove re-ignites when the temperature drops below the set threshold (DELTA RESTART).
Once you have accessed the climate comfort menu, you can operate on the settings dedicated to the function:
ACTIVATE COMFORT: to enable / disable the function
COMFORT MANAGEMENT: to choose whether to enable the climate comfort function based on the water or room temperature
DELTA RESTART: to modify the Delta Comfort climate value
DELAY SWITCH OFF: to modify the Delay Switch Off value
The COMFORT CLIMA function has the purpose of activating the ECO STOP status if the set temperature of the room / boiler water is
kept at the set value for at least "X" minutes (DELAY SWITCH OFF). The stove maintains this state until the room / water temperature
drops below the "Y" value (Y = Set value - DELTA COMFORT CLIMA).
For example, with the Climate Comfort "Air" management, an environment set of 21 ° C, Delta Comfort Clima "5 ° C", Delay Switch
Off "5 min", the stove goes into Modula power when it reaches 21 ° C and if the temperature is maintained for 5 minutes, the stove
switches off (Eco stop). The stove restarts when a temperature of 16 ° C (21 ° C - 5 ° C) is detected.
For example, with a boiler water set of 65 ° C, the stove switches off when it is reached, to restart when a temperature of 60 ° (65 °
C - 5 ° C) is detected.
ACTIVATE COMFORT
Use and maintenance manual RBH 150 V - RBH 200 V
ACTIVATE COMFORT
EN
Rev.2 15/07/2021
Pag.55