Auto-Diagnosis - Bosch WBE 4200 Instructions De Réparation

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

en
42 | WBE 4200 | Menu navigation
5.3.4

Auto-diagnosis

Press the <MENU> key until you see the word t5t and
then access the sub-menu by pressing the <USER> key
within 1.5 seconds.
R
<MENU> - SEt - CAL - TST
Right Display
Left Display
MSR
ex.: 892
ex.: 1338
es.: 180
ex.: 810
ex.: 2
Left Display
Right Display
ENC
Left Display
Right Display
SP
Left Display
Right Display
0
2048
1
2048
2
2048
3
2048
4
500
5
500
6
500
7
8
9
10
Left Display
Right Display
CNT
1
500
6
Left Display
Right Display
LED
Left Display
Right Display
TAR
|
1 695 600 091
2012-11-16
Description
RIM DISTANCE
Press <
> /
RIM DIAMETER
<
>to roll
down menu
1° shown value:
tension measured in left pick-up
2° shown value: tension
measured in the right pick-u
3° shown value: phase angle
difference
4° value: Rounded off ratio
between the pick-ups
Description
It shows the position of the
encoder from 0 to 255
Description
Speed in turn/min of the shaft
Description
Reading analog entry of the
external pick-up
RIM DISTANCE
Press <
> to
roll down menu
Reading analog entry of the
internal pick-up
Reading analog entry of the
enlarged internal pick-up
Reading analog entry of the
enlarged external pick-up
Reading of the sensor of the
distance (no SBM125)
Reading of the sensor of the
width(no SBM125)
Reading of the sensor of the
diameter (no SBM125)
Non used
Non used
Non used
Non used
Description
RIM DISTANCE
Press <
> to
roll down menu
Overall launches (ex:1500)
Daily launches (since when the
balancing machine has been
turned on)
Description
RIM DISTANCE
Press <
> to
roll down menu
Description
RIM DISTANCE
Press <
> to
roll down menu
Left Display
Right Display
I_0
MAG
on/oFF
FLA
on/oFF
BRA
on/oFF
0.UP
on/oFF
O.dU
on/oFF
PFL
on/oFF
PBR
on/oFF
INP
on/oFF
I.UP
on/oFF
I.DU
on/oFF
Left Display
Right Display
REL
oFF
!
NOTE: All the options are described in details on the
following pages.
Description
RIM
Digital entries: press the <
DISTANCE
> button to roll
down the menu
ALUDATA® electromagnet test
Test to the electro valve of the
pneumatic flange
Checks the electro-magnetic
brake activation
Checks hoisting device
solenoid valve
R Ascent check
Checks hoisting device
solenoid valve
R Descent check
Check the opening of the
pneumatic flange
Checks the electro-magnetic
brake activation
State of the carter: OFF open,
ON closed
Lifter up button activation
control
Lifter down button activation
control
Description
Start of the relative balancing
procedure