10.5.4
Calibration with sample weight
i
After Calibration of electronic vernier caliper remove
the wheel from machine.
1. Press the button
until the LED of
flash;
2. Bring the calliper gauge on the flange.
B
Fig. 31:
3. Bring the calliper gauge back to the"Rest position";
Fig. 32:
4. Close the wheel protection cap.
Measurement is started.
The left-hand display shows C-3.
5. Apply the sample weight on the internal side of the
flange.
6. Close the wheel protection cap..
Measurement is started.
The left-hand display shows C-4.
7. Remove the sample weight from the internal side
of the flange and apply it on the external side (12
o'clock).
8. Close the wheel protection cap.
Measurement is started.
The left-hand display shows C-5.
9. Turn the flange until the weight is in 12 o'clock
position and then press <SPLIT>.
The left-hand display shows 0-0.
Robert Bosch GmbH
"
Calibration is completed.
i
The performed calibration is automatically and
permanently saved.
i
After having carried out factory calibration with
button
sample weight, access the standard calibration menu
and perform a new calibration.
Maintenance | WBE 4200 | 59
1 695 600 091
en
|
2012-11-16