11.5 Operating pressure or test pressure
The pressure test has been made with water containing
anti-corrosive additives at a temperature of 68 °F (20 °C).
Operating pressure
[bar]
[psi]
10.3
150
11.6 Inlet pressure
To ensure optimum and quiet pump operation, the inlet pressure,
system pressure, must be adjusted correctly. See the table on
page 210.
For the calculation of specific inlet pressures, contact the local
Grundfos company.
11.7 Electrical data
See sections
31. Technical data, single-phase motors
32. Technical data, three-phase
For specific motor data, see the motor nameplate.
11.8 Sound pressure level
See section
34.2 Sound pressure
11.9 Environment
Non-aggressive and non-explosive atmosphere.
11.10 Installation altitude
Installation altitude is the height above sea level of the installation
site.
Motors installed up to 3281 ft (1000 m) above sea level can be
loaded 100 %.
The motors can be installed up to 6560 ft (2000 m) above sea
level.
Motors installed more than 3281 ft (1000 m) above
sea level must not be fully loaded due to the low
density and consequent low cooling effect of the air.
P2
[%]
1
0.99
0.98
0.97
0.96
0.95
0.94
0.93
0.92
0.91
0.90
0.89
0.88
0
0
3281 3937 4593 5249 5906 6562 7218
Fig. 24 Motor output power in relation to altitude
20
Test pressure
[bar]
[psi]
15.5
225
and
motors.
level.
[ft]
11.11 Humidity
Maximum air humidity: 95 %.
If the air humidity is constantly high and above 85 %, one of the
drain holes in the drive-end flange must be open.
See section
6. Receiving the
product.
11.12 Motor cooling
To ensure cooling of motor and electronics, observe the following:
•
Position the motor in such a way that adequate cooling is
ensured. See section
8.8 Ensuring motor
•
The temperature of the cooling air must not exceed
122 °F (50 °C).
•
Keep cooling fins and fan blades clean.
12. User interfaces
WARNING
Hot surface
Death or serious personal injury
- Only touch the buttons on the display as the
product may be very hot.
WARNING
Electric shock
Death or serious personal injury
- If the control panel is cracked or perforated,
replace it immediately. Contact the nearest
Grundfos sales company.
You can make pump settings by means of the following user
interfaces:
Control panels
•
Standard control panel.
See section
13. Standard control
•
Advanced control panel.
See section
14. Advanced control
Remote controls
•
Grundfos GO Remote.
See section
16. Grundfos
GO.
If the power supply to the pump is switched off, the settings are
stored.
cooling.
panel.
panel.