or
or coloured Green or Green & Yellow.
Connect the Brown wire to the terminal marked "L" or coloured Red.
Connect the Blue wire to the terminal marked "N" or coloured Black.
Adapting the Cooktop for DifferentTypes of Gas
Table1
Burner
Therma
l power
(kW)
Auxiliary
1.0
(Small) (A)
Semi rapid
1.8
(Medium)
Rapid (R)
3.0
Triple Ring
3.6
After you have converted the cooktop to another gas type, make sure you have placed a label
containing that information on the appliance.
Adjustment of the reduced valve flow
Table2
Burners
Regular burners
Burners and Nozzle Specifications
G20
G31
Nozzle
Thermal
Nozzle
1/100
power
1/100
(mm)
kW
(mm)
0.78
1.0
0.5
1.03
1.8
0.67
1.28
3.0
0.85
1.43
3.6
0.95
Replacement of burner nozzle: loosen the nozzle with a dedicated wrench(7).Fit
the new nozzle, suitable for the required gas type (see table above for reference)。
Flame
Full flame
G30-29
G30-37
Thermal
Nozzle
Thermal
power
1/100
power
kW
(mm)
kW
1.0
0.5
1.0
1.8
0.67
1.8
3.0
0.85
3.0
3.6
0.95
3.6
Converting the
cooktop from LPG
to natural gas
Replace the burner
Nozzle according
To the guidelines in
table 1
G30-50
Nozzle
Thermal
Nozzle
1/100
power kW
1/100
(mm)
(mm)
0.47
1.0
0.45
0.62
1.8
0.59
0.81
3.0
0.77
0.89
3.6
0.84
Converting the
Cooktop from natural
Gas to LPG
Replace the burner
Nozzle according
to the guidelines in
table 1