The gas holes are not clogged in the area corresponding to the safety device.
The burner does not remain on when set to "Low".
Check to make sure that:
The gas holes are not clogged.
There are no draughts near tire cooking surface.
Tile minimum has been adjusted correctly (see the section entitled, "Minimum Regulation").
The cookware is not stable.
Check to make sure that:
The bottom of the cookware is perfectly flat.
The cookware is centered correctly on the burner or electric hot plate.
The support grids have not been inverted.
If, despite all of these checks, the cooktop does not function properly and problem persists, call the nearest
Merloni Elettrodomestici Customer Service Centre informing them of:
Tile type of problem.
--
The abbreviation used to identify the model (Mod.... )as indicated on tile warranty.
--
Nover call upon technicians not authorized by the manufacturer, and refuse to accept spare parts that are
not original.
The following instructions are directed at the qualified installer so that the installation and maintenance
proceedures may be followed in the most professional and expert manner possible. Important: Unplug the
electrical connection before performing any maintenance or regulation upkeep work.
Positioning for gas hob
Important: this unit may be installed and used only in permanently ventilated rooms according to the British
Stancards Codes Of Practice: B.S. 6172 / B.S. 5440, Par. 2 and B.S. 6891 Current Editions. The following
requirements must be observed:
a) The room must be fitted with a ventilation system which vents smoke and gases from combustion to the
outside.
This must be done by means of a hood or electric ventilator that turns on automatically each time the
hood is operated.
In a chimney stack or branched flue.
(exclusively for cooking appliances)
b) The room must also allow for the influx of the air needed for proper combustion. The flow of air for
combustion purposes must, not be less than 2 m³/h per kW of installed capacity. The supply of said air
can be effected by means of direct influx from the outside through a duct with a inner cross section of at
least 100cm² which must not be able to be accidentally blocked. Those appliances which are not fitted
Installation Instructions for built-in
Directiy to the Outside