with a safety device to prevent the flame from accidentally going out must have a ventilation opening
twice the size otherwise required, i.e. a minimum of 200 cm² (Fig. 3). Otherwise, the room can be vented
indirectly through adjacent rooms fitted with ventilation ducts to the outside as described above, as long
as the adjacent rooms are not shared areas, bedrooms or present the risk of fire (Fig. 4).
Examples of ventilation holes for comburant air.
Fig.3
c) Intensive and prolonged use of the appliance may necessitate supplemental ventilation, e.g. opening a
Window or increasing the power of the air intake system (if present).
d) Liquidified petroleum gases are heavier than air and, as a result, settle downwards. Rooms in which
LPG tanks are installed must be fitted with ventilation openings to the outside in order to allow the gas
to escape in the event of a leak. Therefore, LPG tanks, whether empty or partially full, must not be
installed or stored in rooms or spaces below ground level'(cellars, ect.). It is also a good idea to keep
only the tank currently being used in the room, making sure that it is not near sources of heat (ovens,
fireplaces, stoves, etc.) that could raise the internal temperature of the tank above 50ºC.
Installation of built-in stove tops
The gas hobs are prepared with protection degree against excessive heating of type X, the appliance can
therefore be installed next to cabinets, provided the height does not exceed that of the hob. For a correct
installation of the cooking hob the following precautions must be followed:
a) The hob may be located in a kitchen, a kitonen/diner or bed sitting room, but not in a bathroom or shower
room.
b) The furniture standing next to the unit, that is highe1 than the working boards, must be placed at least
110mm from the edge of the board.
c) The cabinets should be positioned next to the hood at a height of at least 420 mm (Fig. 5).
d) Should the hob be install-ed directly under a cupboard the letter should be at least 700mm (millimetres)
from the worktop, as shown in Fig. C.
e) The dimensions of the room for the furniture must those indicated in the figures in the last two pages the
cover. Fixing hooks are provided which allow place the hob plate on work tops that measure 20 to 40 mm
in thickness (see Fig. 6).To obtain a of the hob plate it is advisable to use all the fixing supplied.
Detail A
Adjacent Room
Enlarging the ventilation slot between window and floor
Fig.5
Room to be Vented
Fig.4