46 9.2.5 Factory Settings; Calibration With Sample Weight; Flange Calibration; Calibration Of Electronic Calliper Gauge/Measurement Arm - Bosch WBE 4120 Instructions De Réparation

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

en
60 | WBE 4120 / WBE 4120 D / WBE 4120 DT | Calibration
"
The factory calibration menu is displayed.

Calibration with sample weight.

Flange calibration

Back to main page.
Calliper gauge and measurement arm calibration
Factory settings
9.2.2
Calibration with sample weight
i
Keep to the indications displayed on the monitor.
6. Select Calibration with sample weight and confirm
by pressing < I >.
« Calibration is started.
7. Bring the calliper gauge on the flange.
8. Bring the calliper gauge back to stand-by position
9. Press < I > or close the wheel protection cap.
« Measurement is started.
10. Apply the sample weight on the internal side of the
flange.
11. Press < I > or close the wheel protection cap..
« Measurement is started.
12. Remove the sample weight from the internal side
of the flange and apply it on the external side (12
o'clock).
13. Press < I > or close the wheel protection cap.
« Measurement is started.
14. Turn the flange until the weight is in 12 o'clock
position.
15. Press < I >.
"
Calibration is completed.
i
The performed calibration is automatically and per-
manently saved.
i
After having carried out factory calibration with sam-
ple weight, access the standard calibration menu
(see chap. 5.4.1) and perform the calibration with
wheel and sample weight (see chap. 5.4.4).
|
1 695 600 579
2016-08-02
9.2.3
Flange calibration
i
Follow the instructions for the standard calibration
(see chap. 5.4.2).
9.2.4
Calibration of electronic calliper gauge/mea-
surement arm
i
Follow the instructions for the standard calibration
(see chap. 5.4.3).
9.2.5
Factory settings
i
The balancing machine factory configuration can be
defined by enabling and disabling some operations;
i
Scroll the several items of the components inside
the menu with the buttons <o> and <u>;
i
Define the ON/OFF status with the buttons <z> and
<r>.
Description
WBE 4120 DT WBE 4120 DT
Automatic gauge
ON
Width gauge
OFF
Aludata arm
ON
Aludata pedal
OFF
Roundness
OFF
Brake
OFF
Light ring
OFF
Fast cycle
OFF/ON
Bosch Automotive Service Solutions GmbH
+width gauge
ON
ON
ON
OFF
OFF
OFF
OFF
OFF/ON