CHARGE MODES

• Description of charging modes and currents :
Lead-acid CHARGE mode (14.6 V/30 A max) :
Mode designed for the recharge of 12V lead-acid batteries from 15 Ah to 375 Ah. Automatic seven step
charge cycle.
Lithium CHARGE mode (14.4 V/30 A max) :
Mode designed for the recharge of 12 V lithium batteries from 7 Ah to 375 Ah. Automatic eight step
charge cycle.
Charging current 7 / 15 / 30 A :
Selection designed to choose the most suited charging current based on the type and size of the battery
(lead-acid or lithium).
Charging current
Battery capacity
*Lead battery corresponding : A lithium battery has a better starting performance (CCA) than a lead battery. That's why some
lithium battery manufacturers indicate the battery lead equivalent (EqPb) which corresponds to the capacity of a lead-acid battery
with the same starting performance. For instance, a LFP battery of 10 Ah will have the same starting performance as a lead-acid
battery of about 30 Ah.
Mode SHOWROOM (13.7 V / 30 A) :
Mode designed to compensate up to 30 A the current consumed on the battery of a vehicle in demons-
tration by delivering a stabilised voltage of 13.7 V. This mode is suited for lead-acid and lithium batteries.
When the indicator
the current absorbed by the battery is higher than the charger maximum current (30 A) and that the
battery might end up being discharged.
The current supplied by the charger is indicated using the LED indicators
GYSFLASH 30.12 PL
Some Lithium batteries incorporate a UVP protection (Under Voltage Protection) which
disconnect the battery in case of deep discharge. This protection prevents the charger from
detecting the battery. In order for the Gysflash 30.12 PL to be able to charge the battery, it
is necessary to deactivate the UVP protection. To do this, select the Lithium charging mode
and press the button
protection and automatically start charging.
Pb
15
LFP
7
(21
45 Ah EqPb*) (45
Option Supply (13.7 V / 30 A) :
Feature designed to turn the charger into a stabilised power source with a regulated voltage
of 13.7 V and a supply of current up to 30 A. This mode can be used without a battery.
To select this option, place the charger in Showroom mode and press the
until the
indicator flashes.
is on, the voltage is correctly regulated. If indicator
I
0 A
1 A
6.3 A
for 10 seconds. The charger will then deactivate the UVP
7 A
15 A
60 Ah
60
100 Ah
15 Ah
15
30 Ah
90 Ah EqPb*)
7.7 A
13.5 A
16.5 A
30 A
100
375 Ah
30
375 Ah
(90
1100 Ah EqPb*)
flashed, this means that
UK
button
:
27 A
30 A
9