EAS ELECTRIC ML Serie Manual De Instrucciones página 74

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Model E
Model G
CAUTION
After confirmation of the above conditions, follow these guidelines when performing wiring:
• Always have an individual power circuit specifically for the air conditioner. Always follow
the circuit diagram posted on the inside of the control cover.
• Screws fastening the wiring in the casing of electrical fittings may come loose during
transportation. Because loose screws may cause wire burn-out, check that the screws are
tightly fastened.
• Check the specifications for the power source.
• Confirm that electrical capacity is sufficient.
• Confirm that starting voltage is maintained at more than 90 percent of the rated voltage
marked on the name plate.
• Confirm that the cable thickness is as specified in the power source specifications.
• Always install an earth leakage circuit breaker in wet or moist areas.
• The following can be caused by a drop in voltage: vibration of a magnetic switch,
damaging the contact point, broken fuses, and disturbance of normal functioning.
• Disconnection from a power supply must be incorporated into the fixed wiring. It must
have an air gap contact separation of at least 3mm in each active (phase) conductors.
• Before accessing terminals, all supply circuits must be disconnected.
Page 20
Model F
V.2
V.1

Publicidad

Capítulos

Tabla de contenido
loading

Tabla de contenido