MAINTENANCE
MAINTENANCE
Storage
Storage
Storage
Always drain pump when not in use. If pump is to be stored for a month or longer:
1.
Flush with fresh water.
2. Inspect and lubricate impeller; replace if worn or damaged. Refer to
3. Cover suction and outlet ports with tape to prevent anything from entering the pump.
4. Store in a clean, dry area at room temperature.

Troubleshooting

Problem
Pump not connected to battery.
Pump does not
Corroded alligator clips.
turn on
Defective motor.
Air leak in suction line.
Pump will not
prime or loses
Suction lift is too high.
prime
Damaged impeller.
Damaged impeller.
Pump runs but
Suction lift is too high.
does not dis-
Inlet to impeller plugged.
charge fluid
Lift too high for pump.
Pump does not
Partially blocked inlet.
deliver rated
Impeller or discharge hose is clogged.
capacity
Impeller wear due to abrasives.

Replacement Parts and Accessories

Item
Part Number
1
14942029
2
14942028
For technical assistance, parts, repair, or warranty information, please contact:
888.885.9254 | redlionproducts.com
Form 998774 Rev. 001 03/20
Probable Causes
Description
Items
Impeller (qty 2)
Impeller Kit
Gasket (qty 2)
Spring Strainer (qty1)
Suction Attachment (qty 1)
Accessory Kit
6 ft. (1.8 m) Reinforced Hose
(qty 1)
"Impeller Replacement" on page
Corrective Action
Connect pump power
lead wires
ing and Starting the Pump" on page
Clean clips on lead wires.
Replace pump.
Locate and eliminate air leak in suction line.
Reduce the pump height to water source.
Replace impeller. Refer to
"Maintenance" on page
Replace impeller. Refer to
"Maintenance" on page
Reduce the pump height to water source.
Check inlet; clean if plugged.
Pull pump and clean, refer to
Check rated pump performance.
Pull pump and clean, refer to
Pull pump and clean. Check hose for kinks or blockage.
Replace pump.
1
2
3.
to battery terminal. Refer to
3.
3.
3.
"Maintenance" on page 3
"Maintenance" on page 3
Copyright © 2020, Franklin Electric, Co., Inc. All rights reserved.