• Press [MR] to open the accumulation display
• Press [Print M+] to print
• Press [CE] to clear the accumulation.
• Press [Zero]/
Steps:
Add the weight and press [Print M+] when the display is at zero.
The display will show "ACC 1" and then the weight in memory for 2
seconds before returning to normal. The weight can be output to a printer or PC using the
RS-232 interface.
When the scale is at zero, place a second weight. When stable, press [Print M+] to
accumulate the weight. The display will show "ACC 2" for 2 seconds and then show the new
total.
Continue until all weights have been added. This can continue for up to 99 entries until the
capacity of display is exceeded.
To view the total in memory, press the [MR] key when the scale is at zero. The display will
show the total number of accumulation "ACC xx" and the total weight.
To print the total, press [MR] to recall and then immediately press [Print M+] to print the
results. To erase the memory, press [MR] to view the total and then immediately press [CE]
to clear the memory.
Press [Zero]/
Esc
0
Automatic Accumulation
When the scale has been set to Automatic Accumulation the value will be stored in memory
automatically.
Steps:
Place a weight on the platform. The beeper will sound when the display is stable indicating
the value is accepted. Remove the weight. The display will show "ACC 1" and then the total in
the memory before it returns to zero. Adding a 2nd weight will repeat the process.
While the weight is on the platform, press the [MR] key to view the values- first the
accumulation number "ACC x" and then the total will be shown.
NOTE: The scale must return to zero or a negative number, before another sample can be
added to the memory.