If the light is not dimmed via button within 1 minute, the lighting will
switch off again automatically. If the lighting is dimmed, the light
channels will remain on for as long as movement is detected.
The preset time setting will start once movement is no longer detected.
Provided that no further movement is detected during this period,
the lighting will switch off once this set time has elapsed. Channel S1 or S2
can also be manually switched on or off by its button.
Semi-automatic mode for HVAC channel C3
Light is switched on manually using the S3 button, no automatic activation.
If no further movement is detected, the time setting will start for C3.
C3 will be switched off once this set time has elapsed. C3 can also be
switched on or off at any time using the S3 button.
Corridor semi-automatic mode for light channel C1 – C2
Light is switched on manually using the S1 or S2 button, no automatic
activation. If the ambient lighting level is darker than the set target value,
the light channels are adjusted to this preset target value. These will
remain on for as long as movement is detected and as long as the ambient
light value does not exceed the respective set value. However, if the
ambient lighting level is brighter than the preset target value, the light
channels are adjusted to 100 % of the luminous efficiency. They remain
on while movement is being detected, regardless of the ambient
lighting level. Light channels C1 + C2 cannot be switched off by button.
HVAC channel C3
The HVAC channel C3 is switched on when movement is detected,
regardless of the ambient light value. The time settings for the
respective channels will start if movement is no longer detected.
HVAC channel C3 can be manually switched off using the S3 button.
Orientation light
The orientation light is an adjustable basic light. The luminous
efficiency can be set to between 10 % and 40 % of the full
luminous efficiency.
Afterglow feature
The orientation light switches on for an adjustable period of time once
movement is no longer detected and the preset time setting
has elapsed.
Night-light feature
If no movement is detected, the orientation light switches on at the
preset orientation light value when the ambient light level falls below
the preset light value. It remains on until a movement is detected or
until the preset light value is exceeded.
8 • SETTINGS AND FUNCTIONS VIA MOBIL-PDi/plus
REMOTE CONTROL (FIGS. 6.1 + 6.2)
NOTE: To get the best possible reception, point the remote control at the
detector during programming. Please note that if the sun shines directly
onto the sensor, the standard detection range of approximately 8 m may
be reduced by the sun's infrared rays.
Please take note of the modified remote control (fig. 6.2). All functions
can also be carried out using the previous version (fig. 6.1).
Temporary functions
The functions are carried out as soon as the button has been pressed,
but they are not stored.