Descargar Imprimir esta página

Description And Technical Description; Description; Technical Description; Standard Equipment - CEMONT BLUMIG 303S Instrucciones De Seguridad, Empleo Y Mantenimiento

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 18
EN
1.0
DESCRIPTION AND TECHNICAL DESCRIP-
TION
1.1

DESCRIPTION

MIG/MAG welding professional generators, three-phase feeding,
forced ventilation, prepared for separated wire pulling set.
1.2

TECHNICAL DESCRIPTION

DATA PLATE
250 A
PRIMARY
Three phase supply
Frequency
Effective consuption
Maximum consuption
SECONDARY
Open circuit voltage
Welding current
Duty cycle 30%
Duty cycle 60%
Duty cycle 100%
Protection class
Insulation class
Weight
Dimensions
European Standards
300 A
PRIMARY
Three phase supply
Frequency
Effective consuption
Maximum consuption
SECONDARY
Open circuit voltage
Welding current
Duty cycle 35%
Duty cycle 60%
Duty cycle 100%
Protection class
Insulation class
Weight
Dimensions
European Standards
All manuals and user guides at all-guides.com

DESCRIPTION AND TECHNICAL DESCRIPTION

230 V
400 V
50 Hz
15 A
8,5 A
27 A
15,6 A
18 ÷ 40 V
35 A ÷ 250 A
250 A - 26,5 V
170 A - 22,5 V
140 A - 21 V
IP 23
H
Kg. 77
mm 500 x 880 x 950
EN 60974.1 / EN 60974.10
230 V
400 V
50 Hz
20 A
11,3 A
33 A
19 A
18 ÷ 45 V
40 A ÷ 300 A
300 A - 29 V
230 A - 25,5 V
180 A - 23 V
IP 23
H
Kg. 93
mm 500 x 880x 950
EN 60974.1 / EN 60974.10
3 EN
350 A
PRIMARY
Three phase supply
Frequency
Effective consuption
Maximum consuption
SECONDARY
Open circuit voltage
Welding current
Duty cycle 35%
Duty cycle 60%
Duty cycle 100%
Protection class
Insulation class
Weight
Dimensions
European Standards
450 A / 450 A H
PRIMARY
Three phase supply
Frequency
Effective consuption
Maximum consuption
SECONDARY
Open circuit voltage
Welding current
Duty cycle 35%
Duty cycle 60%
Duty cycle 100%
Protection class
Insulation class
Weight
Dimensions
European Standards
1.3

STANDARD EQUIPMENT

For models 250A, 450A and 450AH
- Earth cable
For models 300A and 350A
- Earth cable
- Digital instruments
1.4

DUTY CYCLE AND OVERHEATING

The duty cycle is the percentage of a 10 minute period for which
the welder can continue to weld without overheating. If the ma-
chine overheats, the welding current is shut off and the relative in-
dicator lamp illuminates. In this case, leave the machine to cool for
approx. 15 minutes and, before restarting, lower the welding cur-
rent value and relative voltage or reduce the work time.
Example: 400 A - 60% means working for 6 minutes at 400 A with
4 minutes rest time.
1.5

VOLT - AMPERE CURVES

The volt-ampere curves show the welder's maximum output cur-
rents and voltage (see page XVI - XVII).
230 V
400 V
50 Hz
25 A
14,5 A
42 A
24 A
18 ÷ 46 V
35 A ÷ 350 A
350 A - 31,5 V
270 A - 27,5 V
210 A - 24,5 V
IP 23
H
Kg. 108
mm 500 x 880 x 950
EN 60974.1 / EN 60974.10
230 V
400 V
50 Hz
35,5 A
20,5 A
60 A
34,5 A
19 ÷ 54 V
51 A ÷ 450 A
450 A - 36,5 V
345 A - 31,3 V
270 A - 27,5 V
IP 23
H
Kg. 140
mm 600 x 950 x 1050
EN 60974.1 / EN 60974.10

Hide quick links:

Publicidad

loading

Este manual también es adecuado para:

Blumig 353sBlumig 403sBlumig 503sBlumig 503sh