CountyLine CLTS5 1/2 HP Manual Del Usuario página 5

Bombas de chorro en hierro fundido
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Installation
To Install a Shallow Well Pump
For wells 25 feet or less in depth, the 1/2 HP CLTS5 and
1 HP CLTS10 pumps are recommended. However, the
1/2 HP CL520 and 1 HP CL100 convertible pumps may
be adapted to shallow wells with an ejector kit.
General Materials Required
One can PVC cement (read instructions carefully)
One roll PTFE pipe thread sealant tape
One 1-1/4" foot valve
Two male 1-1/4" PVC adapters
Enough rigid 1-1/4" PVC pipe and couplings to reach
from bottom of well to pump
One well seal with vent plug
One 1-1/4" PVC elbow
One discharge tee
One pressure gauge
Reminder: All joints and connections must be airtight . A single pinhole leak will prevent the proper operation of
the pump . Use PTFE pipe thread sealant tape on all threaded joints unless specified otherwise .
1. Thread 1-1/4" male PVC
adapter into foot valve. Hand
tighten, then tighten 1/4 turn
with crescent wrench. Seal
the threaded pipe joints with
PTFE pipe thread sealant
tape or PTFE-based pipe joint
compound approved for use
on PVC.
2. Subtract five feet from the depth
of your well (see Determine the
Depth of Your Well). This is the
total length of rigid PVC pipe
and couplings to cement onto
the 1-1/4" male PVC adapter.
Cement one section of rigid PVC
pipe to the PVC adapter which is
connected to the foot valve, then
lower the whole assembly into the
well, foot valve first. Firmly clamp
the end of the rigid PVC pipe with
a pipe clamp to prevent the assembly from sliding
down into the well.
One male 1" PVC adapter
Enough rigid 1" PVC pipe to reach from pump to
pressure tank to service line
One female 1" PVC adapter
One 1" tank cross (for diaphragm tanks)
Two 1/4" plugs
One 1/2" drain cock
One 10" x 1" nipple
In addition to General Materials, for the CL520, or
CL100 Convertible only:
One ejector kit; includes ejector, venturi tube,
gasket, bolts, plug, tubing, and fittings.
Tools needed for all pump installations
Pipe wrench, pipe clamp, crescent wrench, slot
screwdriver, 24-tooth hacksaw, knife or round file.
3. Cement as many couplings and sections of rigid PVC
pipe as it takes to equal the depth of your well minus
1-1/4"
MALE PVC
five feet, then firmly clamp the assembly with a pipe
ADAPTER
clamp to prevent the assembly from sliding down
into the well.
FOOT
VALVE
To Household
Water System
PVC
PIPE
SECTION
1-1/4"
MALE PVC
ADAPTER
FOOT
VALVE
Not
to
Scale
Pump Priming
Tee with Plug
or Gauge
Suction Pipe
From Well
Priming
Check
Tee and
Valve
Plug
Sanitary
Well Seal
10'
Foot
Min.
Valve
5–10'
1862 0205 SWJ
5

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Clts10 1 hpCl520 1/2 hpCl100 1 hp

Tabla de contenido