10

Display function modes

10.1

Parameter display mode

PARAMETER
PARAMETER
See chapter 13 for detailed descriptions of parameters.
10.2

Command and safety device status display mode

COMMAND STATUS
AP
PED
PP
CH
ORO
POWER
COMMAND STATUS:
The command status indicators on the display are normally OFF.
They ILLUMINATE when a command is received (e.g.: when a step mode command is received, the segment PP
illuminates).
SEGMENT
COMMAND
AP
open
PP
step by step mode
CH
close
PED
partial opening
ORO
clock
SAFETY DEVICE STATUS:
The safety device status indicators on the display are normally ON.
If an indicator is OFF, the relative device is in alarm state or is not connected.
The an indicator is FLASHING
SEGMENT
SAFETY
FT1
photocell
FT2
photocell
COS1
sensing edge
COS2
sensing edge
FA
gate open limit switch
FC
gate closed limit switch
SB
release handle open
VALUE
SAFETY DEVICE STATUS
FT1
COS1
COS2
SB
STOP
FT2