Setting safeguarded closure/opening activation time
N.B.: this parameter is not visible if the value of parameter
Wait time settable from 2 to 90 s.
Wait time settable from 2 to 9 min.
Selection of the battery operation management
Setting a value different than
selected via parameter
and an error alert can be activated through the COR output via parameter
The control unit always accepts commands until the battery is completely exhausted.
The command becomes active when the battery voltage drops to the minimum threshold (22Vdc for battery 2x12Vdc)
The command becomes active when the battery voltage drops to the medium threshold (23Vdc for battery 2x12Vdc)
The command becomes active when the battery voltage drops to the maximum threshold (24Vdc for battery 2x12Vdc)
Selecting the battery operation limitations.
N.B.: the parameter is visible only if par.
There is no limitation for the commands when the battery voltage drops under the selected threshold. An error alert
may be activated via the COR output (if parameters
When the battery voltage drops under the threshold selected with par.
commands and does not perform closing.
When the battery voltage drops under the threshold selected with par.
automatically opens the barrier's boom and accepts only a closing command.
It accepts only closing commands (if the ORO input is active, it accepts closing commands only if
Selection of the battery type and consumption reduction
Battery 24Vdc (2x12V). Acceleration/deceleration/speed reduction enabled, to increase the battery life.
Battery 24Vdc (2x12V). No performance reduction, maximum battery consumption.
Restoring factory default values
NOTE This procedure is only possible is NO data protection password is set.
+
P1
P2
-
Warning! Restoring default settings cancels all settings made previously except for parameter
check that all parameters are suitable for the installation.
The default factory settings may also be restored using the PLUS + and/or MINUS - buttons as follows:
• Turn off the power.
• Press and hold the PLUS + and/or MINUS - button until the unit switches on.
• The display flashes after 4 s
• The default factory settings have now been restored.
N.B.: The values shown in the table are indicative only.
HW version.
Year of manufacture.
Week of manufacture.
Serial number.
FW version.
a battery voltage level check is activated. The desired operation type can be
is different than
and
x4 s
.
=
.
are adequately set).
, the control unit accepts only opening
, after a 5 s pre-flashing, the control unit
to
.
Example:
.
).
: after restore,
81