1.  Shut off the work light and disconnect the power
cord. 
 
1.  Move the power switch to the Off position. 
2.  Disconnect the power cord from the wall outlet or
power generator. 
2.  Lower the mast.  
 
1.  Hold the inner mast, then pull the latch spring pin
and rotate it 90°. 
2.  Fully lower the inner mast. 
3.  Rotate the latch spring pin 90° and engage the hole
in the inner mast. Be sure the latch spring pin is fully
seated in the hole. 
Maintenance

General Maintenance

WARNING
Shock Hazard.
Contact with high voltage could result in death or serious
injury. Turn off the unit and disconnect the power cord
before you do maintenance.
Burn Hazard.
Contact with hot surfaces could result in death or serious
injury. Wait 10 minutes after turning the unit off before you
do maintenance.
• Make sure that the unit is in good operating condition.
See Preparing the Unit for Use .
• Make sure that no components are missing, worn or
damaged.
WARNING
Do not operate the unit with missing, worn or damaged
components. Death or serious injury could result. Contact
your authorized dealer for service.
• Make sure that all the hardware on the unit is tight.
• Wipe down the unit with a damp cloth to remove dust, dirt
and debris.
• Occasionally apply a small amount of grease to the
wheels.
Location of Serial Number Plate
The serial number plate for the work light is located on the
end of the base near the power switch. 
Location of Weight and Power
Information
 Information on the weight of the work light is located on top
of the base near the mast. 
 Information on the electrical requirements for the work light
is located on top of the base near the mast and next to the
weight decal. 
Troubleshooting
Problem
No light
1. Unit not plugged in. Plug unit into power source.
2. Power switch turned off. Turn power switch to ON.
3. Base cable not connected to fixture cable. Connect base
cable to fixture cable.
4. Unit malfunction. Contact authorized dealer.
Specifications
Dimensions
Description
Overall Length
Overall Width
Possible Cause
In
28.7
24.5
Cm
72.8
62.2
9