Dipswitch
Description (SW7 OFF)
SW5
Used to adjust the integration time. In combination with SW1-3 they
SW6
establish a threshold value; SW5-6 establishes a cumulative alarm
signal value which, when exceeding the threshold value, triggers
an alarm event.
SW7
Used to determine Stand Alone or BUS mode (Ensure that the J12
position (as below) matches the SW7 spec. )
ON: BUS
*OFF: Stand Alone
Used to determine Local or Remote Test
ON: Local. An internal self test is performed every 24 hours from
power-up. Test failure lights up the LEDs (see the Testing the
SW8
Detector section) and the LEDs remain lit until the next self test.
*OFF: Remote. A test is activated whenever the TEST input is
connected to GND. If the test passes, the alarm relay opens for
three seconds.
External test generator
SW9
ON: Enable External Test Generator
*OFF: Disable (internal test)
Used to enable the temperature sensor (alarm temperature
SW10
threshold of +85°C (+185°F))
ON: Enable
Used to determine LEDs operation
SW11
ON: Enable
SW12
Not used
BUS MODE
Dipswitch
SW1-5
SW7
SW6,8-12
SW5
SW6
Duration (in sec.)
*OFF
*OFF 10 (example: vending machine)
ON
OFF
26
OFF
ON
46
ON
ON
80 (example: bank vault)
*OFF: Disable (No temp. threshold is set)
*OFF: Disable
Description
BUS Address
ON: BUS
Not Applicable
8
Low
Sensitivity
High
Sensitivity