Attach to the concrete surface, using the supplied mounting screw in this hole
opening.
The external test generator can be used to:
 Periodically verify proper functioning of the detector
 Observe the detector's sensitivity during installation
To use the test generator:
Connect the test generator to J2 on the PC board (with the polarity resulting
from the red wire connected to the plug pin closest to the terminal block, in
other words, the lowest)
Switch SW9 to ON.
Attach the test generator to the concrete surface.
Perform test, as follows:
a.
b.
Specifications
Coverage
Operating voltage
Current consumption
RFI immunity
Alarm contacts
Tamper contacts
Alarm contact hold time
Operating temperature
Storage temperature
Ingress protection (IP) rating
Impact Rating
RFI immunity
Dimensions (L x H x W)
Weight
In order to continue improving the product, RISCO Group reserves the right to
change specifications and/or designs without prior notice.

Ordering Information

Model
RK66S
For remote test, see the DIPSWITCH Settings section
For calibration test, Switch SW8 to ON and observe the LEDs
Up to 5 meters (16 feet) radius
9 to 16 VDC
Typically 20mA @ 12VDC
According to EN50130-4
24VDC, 0.1A, N/C and N/O
24VDC, 0.1A
2.5 seconds
-40°C to +70°C (-40°F to 158°F)
-50°C to +70°C (-58°F to 158°F)
IP43
IK08
According to EN50130-4
102 X 27.5 X 80.2 mm
(4.0" X 1.1" X 3.2")
220 g ( 7.7 oz)