62
2. Fix the exceeding portion of the signal cable to the outdoor unit.
3. Fix the piping to the wall (after having insulated and wrapped it
with tape).
4. Seal the hole in the wall that allows the pipes to pass through, to
prevent air or water from entering.
indoor unit final test
• Does the system turns ON and OFF correctly and the fan operates
normally?
• Does the system work correctly on all the different modes?
• Do temperature and TIMER features operate properly?
• Do all indicator lights turn on normally?
• Does the SWING feature operate normally?
• Is the condensed water correctly drained?
outdoor unit final test
• Is there any abnormal noise or vibration during operation?
• Could the noise, the air flow or the condensed water drainage dis-
turb the neighbors?
• Is there a refrigerant leakage?
Note: The electronic control allows the compressor to be restarted
three minutes after the system has been turned on again.
Indoor
Wall
Gasket
Outdoor