64
Tightening torque for protection caps and flare connections.
Pipe
diameter
1/4
(6 mm)
3/8
(9,5 mm)
1/2
(12,7 mm)
5/8
(15,9 mm)
wiring diagrams
For 5k, 7k, 9k, 12k and 18k Cool-Only models
BL
Blue
BR
Brown
GN
Green
RD
Red
WH
White
YE
Yellow
For 7k, 9k, 12k and 18k Cool/Heat Models
BL
Blue
BR
Brown
GN
Green
RD
Red
WH
White
YE
Yellow
Tightening
Equivalent Stress
torque
(using a 20 cm
N·m
wrench)
15-20
Ajuste a muñeca
31-35
Ajuste con brazo
35-45
Ajuste con brazo
75-80
Ajuste con brazo
Indoor Unit
Power
Supply
Outdoor Unit
Indoor Unit
Power
Supply
Outdoor Unit
Tightening
Tuerca válvula
servicio
Tapa de
protección
For 22k, 24k, 28k and 30k Cool-Only Models
(For 9k, 12k, 18k and 24k Cool/Heat
models of the Northamerican market).
Indoor Unit
BL
Blue
BR
Brown
GN
Green
RD
Red
WH
White
Outdoor Unit
YE
Yellow
Power
Supply
For 22k, 24k, 28k and 30k Cool/Heat Models
(For 9k, 12k, 18k and 24k Cool-Only
models of the Northamerican market).
Indoor Unit
BL
Blue
BR
Brown
GN
Green
RD
Red
WH
White
Power Supply
YE
Yellow
Outdoor Unit
torque
N·m
7-9
25-30