Chapter 1
Product Overview
Table 1-2
DC Output LEDs (continued)
Color
Amber
Blinking amber and
green
Select and Standby/Active Buttons
Note
Step 1
Step 2
Step 3
78-17647-02
DC Output Status
The RPS 2300 is unavailable. It is providing power to another connected
device.
When you press the Select button, the DC output LEDs display the status of
each port. When you select the desired port, the LED for that port blinks amber
and green.
The RPS 2300 has a Select button and a Standby/Active button on the front of
the fan module. You can use these buttons to select an RPS port to place the RPS
2300 or an individual port in active or standby mode.
shows the Select and Standby/Active buttons.
Use the Select button to select all RPS ports or an individual port.
•
Use the Standby/Active button to change the selected port (or all ports)
•
between standbymode (blinking amber) and active mode (solid green). The
STDBY/ACTIVE LED displays the port status.
The RPS 2300 and all DC ports are in active mode when it powers up.
To change the RPS 2300 or an individual port to standby or active mode, follow
these steps:
Press the Select button. When you press it the first time, all ports are selected, and
all six port LEDs blink amber and green.
Continue pressing the Select button until the desired port blinks amber and green.
Press the Standby/Active button to place the port in either standby or active
mode.
Cisco Redundant Power System 2300 Hardware Installation Guide
Front Panel Description
Figure 1-8 on page 1-13
1-11