TROUBLESHOOTING
WARNING:
the snow blower. Always protect your hands by wearing gloves when performing any
maintenance on the snow blower auger or scraper.
PROBLEM
Snow blower is not
starting.
The motor is on but the
auger does not turn on.
The LED light button is
insensitive to the first
pressing.
The LED indicator on the
battery keeps on after the
snow blower auger stops
working or self-propel
system turns off.
34
56V LITHIUM-ION CORDLESS SNOW BLOWER — SNT2400/SNT2400-FC
Always remove the battery pack(s) when servicing or transporting
CAUSE
◾
Battery charge is low.
◾
The auger-switch trigger is
not depressed at the moment
of the LED indicator flashing
green.
◾
The auger is frozen by snow
or ice.
◾
The battery is overteated. The
LED indicator on the battery
flashes orange or shines red
(see the section "BATTERY
HIGH-TEMPERATURE
PROTECTION" in this
manual).
◾
The shear pin is broken.
◾
The internal self-checking
process causes a slight
delay in the first keystroke
response.
◾
The electric circuit is in
standby for next restart.
The LED will shut off
automatically if the snow
blower is not operated in 5 to
10 mintues.
SOLUTION
◾
Charge the battery.
◾
Press the auger switch trigger
when the LED indicator blinks.
If the LED indicator stops
blinking, the snow blower will
not be response to the pressing
of auger-switch trigger.
◾
Remove the battery pack(s)
firstly, use the supplied chute
clean tool to clear the snow or
ice that obstructs on the auger.
Restart the snow blower.
◾
Remove the overheated battery
from the snow blower and
wait until the battery pack
cools down to approximately
152°F (67°C), then reinstall the
battery and restart the snow
blower.
◾
Replace the shear pin following
the section "REPLACING THE
SHEAR PIN" in this manual.
◾
Press the LED light button and
hold for 1 second.
◾
Just leave it or remove the
batteries from the battery
compartment.