Q
marathon Pro
II
a) Manual Memorisation.
To save the code press the programming button TRANSMITTER PROG for 1.5 seconds.
There is an audible beep, the red indicator LED lights which, when the button is released, remains on, indicating
that the equipment is ready to memorise a transmitter code. From this moment, any code received will be
memorized. To do so, activate the transmitters using the function desired to be saved in the automatic device.
Memorization is confirmed by a red indicator LED flashing and a beep. The unit automatically exits the
memorisation mode 10 seconds after receiving the last code. This is indicated by the red LED turning off and two
short beeps.
b) Memorisation by radio using another transmitter (Microswitch N° 6 ON).
To use this system, at least one
code must have been previously memorised using system "a"). Press the special function of on one of the
previously memorised transmitters so the equipment enters the code memorisation sequence. A red LED
indicator will light up and a long beep will be heard. From this point, any code received with the same function
with which the transmitter used with special function was memorised will be saved. To do so, activate the
transmitters with the same function previously stored by the transmitter used for this system. To save a different
function, use system "a"). Memorization is confirmed by a red indicator LED flashing and a beep. The unit
automatically exits the memorisation mode 10 seconds after receiving the last code. This is indicated by the red
LED turning off. The mode may be exited prematurely by pressing the special function on one of the memorized
transmitters.
Cancelling all Codes.
All codes can be cancelled by "resetting" the memory. Press the TRANSMITTER PROG button for about 4 seconds, a
burst of flashes of the red LED and a series of quick beeps indicate they all previously stored codes have been
erased.The equipment will remain in the code memorisation sequence, awaiting new codes.
Memory Full Indicator.
If the available memory is full, after memorizing 255 different codes, attempts to memorize further codes will be
met by the red indicator red LED flashing and a beep lasting 10 seconds.
WARNING:
Defective Hall Sensor
If the Hall sensor is faulty, the drive can operate in "EMERGENCY" mode.
To operate without a Hall sensor, proceed as follows in this order:
a) Disconnect the power supply.
b) Disconnect the white wire from terminal N° 3 (Signal).
c) Using a wire jumper, bridge terminals N° 3 (Signal) and N° 22 (Test-Photo).
d) Connect the power supply, 2 beeps will be heard, ATTENTION: At this point the installation will work without the
built-in safety measures.
Once the Hall sensor has been replaced, reactivate it by following the above steps in reverse order: "a" disconnect
the power supply, "b" remove the jumper between N° 22 and N° 3, "c" connect the white wire to terminal N° 3 and
"d" connect the power supply again. " There will be no acoustic signal, and the installation will return to normal
operation. The drive power level must be properly regulated again so that the installation
complies with
Applicable Regulations.
It is extremely important for safety reasons to replace the Hall Sensor as quickly as possible, otherwise the
installation may cause serious harm to people.