Chapter 5. Safety standards

5.1. Warnings

During the work phases pay attention to all hot parts of the machine. The temperature
they can reach is so high that it can cause burns! (figure 5.1.A page 53).
Do not touch the transport belt while it is moving! (figure 5.1.A page 53).
It is forbidden to smoke when the machine is working!
In case of blocking of the machine or in order to stop it during the working cycle press EMERGENCY
PUSHBUTTON (figure 5.1.B page 53).

Chapter 6. Ordinary maintenance

6.1. Precautions for ordinary maintenance interventions

ORDINARY MAINTENANCE, MUST BE EXECUTED BY QUALIFIED STAFF APPROPRIATELY TRAINED.
Before proceeding to maintenance, switch the machine off and disconnect it by operating on the
master switch and wait for the machine to cool down!
It is recommended to use protection gloves during maintenance operations!

6.2. Lubrication

Periodically lubricate the conveyor belt chains using lubricant for high temperature such as:
!
grease with silicone
!
non melting grease
(figure 6.2. page 53).

6.3. Plastic film and other scrap removal

It is very important to periodically clean the tunnel inside so to remove all scraps (figure 6.3. page 53).
Wait for the tunnel to cool down properly before cleaning it!

6.4. Machine cleaning

Use a cloth moistened with water for tunnel cleaning.
Do not use solvents but common detergents

6.5.1. Wiring diagram (Tunnel 50)

(figure 6.5.1. page 54/55).
BT1
Thermocouple
ER1
Resistor 1
ER2
Resistor 1
ER3
Resistor 1
F0
Auxiliary fuse
F1
Transformer inlet fuses
F2
Inverter fuses
F3
Fan motor fuses
F4
Resistors fuses 1
FU2
Board fuse
FM1
Fan motor guard 1
M1
Fan motor 1
M2
Belt motor
Q1
Main switch
QM0
Inverter contactor
QM1
Fan motor contactor
QM2
Resistors contactor 1
S0
Emergency pushbutton
SK1
Control board
T1
Auxiliary transformer
TS1
Inverter
13