05. TROUBLE SHOOTING.
PROBLEM
SOLUTION
Suction, but
Check whether the vacuum seals are deformed.
the seal is not
If they are deformed, replace them and try to carry out the process again.
automatically
Check whether the Edge of the bag covered the suction vent. If so, please place
activated
the bag in the correct position.
The lid cannot close. Keep at least 6cm from the sealing bar until the product put
in the bag to prevent it being trapped when lowering the lid.
If this is the case, remove some food, clean the bag and try to carry out the
process again.
Check whether the bags are broken.
If so, use a new bag and carry out the process again.
No suction, but
Check whether the bag is correctly placed in the vacuum chamber.
seal function
Check whether the edge of the bag is obstructing the air suction vent. If so, please
operates
place the bag in the correct position.
Check whether the Edge of the bag has liquid, specks of oil or any particle.
If so, clean the edge of the bag and carry out the process again.
Check whether the edge of the bag is wrinkled.
If so, remove some food so that the bags have sufficient space for sealing,
straighten the mouth of the bag and carry out the process again.
Check whether the packaged foods have sharp edges.
Please wrap the foods in safety paper before putting them in the packing bags.
Inflation of bags
Check whether the packaged foods are susceptible to fermentation. If so, they must
after vacuum
be frozen or refrigerated after vacuum packing to prolong their lifespan.
packing
Undertaking vacuum packing does not guarantee that foods will not decompose.
All fresh vegetables, fruits and seeds are not suitable for storage at ambient tempe-
rature after undertaking vacuum packing. They photosynthesise and breathe. Keep
them refrigerated.
The recipient
1. Ensure that the adapter is properly connected to both the device and the
does not create a
recipient.
vacuum
2. Check that the recipient selector is in the correct position.
3. Position the lids or tube adaptor at the start of suction to prevent leaks.
4. Check whether there is significant damage or breakage, and if so, change for
a new one.
5. Check the selected function on the packing machine.
6. Ensure that the seals of the recipient are clean.
If your problem is not resolved, contact your Technical Assistance Service.