OPERATION
The hood is operated using the (5) push buttons located on the front edge of the
hood.
The Light Off switch turns the lights off and on.
The Light Intensity switch increases and decreases the lighting level.
The Blower Off /Speed switch turns the blower off and changes blower speed to four
diff erent speed settings: high, medium-high, medium-low and low speed. Depress
and hold the button for 2 seconds to turn the blower off .
The Blower On/Speed switch turns the blower on to four diff erent speed settings:
Low, medium-low, medium-high and high speed.
The LED Display:
• Indicates blower speed selection from 1 (lowspeed) to 4 (high speed).
• Flashes the blower speed when the 10-minute delay off has been activated.
• After 30 hours of operation, the center segment of the display blinks and remains
lit, indicating that the fi lter needs to be cleaned.
The Delay off feature: When pushed, the blower will continue to operate at the
current speed setting for 10 minutes before automatically turning itself off .
The Filter Alarm Reset switch is used to reset the 30-hour fi lter timer. After the
fi lter is cleaned or replaced, press this switch once to reset the fi lter clean alarm.
Light OFF
Light
Intensity
HEAT SENTRY™
Your hood is equipped with a HEAT SENTRY™ thermostat. This thermostat is a
device that will turn on or speed up the blower if it senses excessive heat above the
cooking surface.
1) If blower is OFF - it turns blower ON to HIGH speed.
2) If blower is ON at a lower speed setting - it turns blower up to HIGH speed.
When the temperature level drops to normal, the blower will return to its original setting.
WARNING
The HEAT SENTRY thermostat can start the blower even if the hood is turned
OFF. When this occurs, it is impossible to turn the blower OFF with its switch.
If you must stop the blower, do it from the main electrical panel.
REMOTE CONTROL:
An optional ACR Series remote control (purchase separately) can be used to
operated the power pack.
Blower Off /Speed
Blower On/Speed
- 8 -
LED Display
Delay off /
Filter Alarm Reset