Electrical
Disconnect power before working on pump, motor, pressure switch, or wiring.
Motor Terminal Board Connections:
Your Motor Terminal Board (under the motor end cover)
looks like one of those shown below. If necessary, convert
to 115 Volts as shown. Do not change motor wiring if line
voltage is 230 volts or if you have a single voltage motor.
230 Volt to 115 Volt Conversion.
230 V
A
A
L 2
L 2
L 1
L 1
230 Volt to 115 Volt Conversion.
1.
Pull plug
straight
out from
terminal
board.
A
1.
L1
230 Volt to 115 Volt Conversion.
2 3
0
1 1
5
Power
Supply
Ground Screw
Wires
Clamp power cable to avoid strain on terminals.
Connect the green (or bare copper) ground
wire to the green ground screw.
Figure 6A: Motor wiring connections through Pressure
Switch. Match motor voltage to line voltage.
For parts or assistance, call Simer Customer Service at
Move plug to change voltage.
Ground
Screw
115 V
A
A
L 2
L 2
L 1
L 1
Power Supply
Wires
Move plug to change voltage.
2.
Plug in again
Ground
with arrow
Screw
on plug
pointing to
'115 Volts'.
2.
A
L1
3962 0401 A
Move plug to change voltage.
230 V
2 3
0
1 1
5
115 V
2 3
0
1 1
5
3994 0501
Pressure Switch Connections:
Your Pressure Switch looks like one of those shown below.
Connect power supply as shown for your type of switch
and your supply voltage.
Motor wires connect here.
Power supply wires connect here.
230 Volt: Connect 2 hot wires (black and red)
here and cap the white (neutral) wire. It does
not matter which wire goes to which screw.
115 Volt: Connect one hot wire (black or red)
to one of these screws (it doesn't matter
which one). Connect the white (neutral) wire
to the other screw. Cap any remaining
black or red wires.
Clamp the power cable to prevent strain
on the terminal screws.
Connect the green (or bare copper) ground wire
to the green ground screw.
Motor wires connect here.
Power supply wires connect here.
230 Volt: Connect 2 hot wires (black and red)
here and cap the white (neutral) wire. It does
not matter which wire goes to which screw.
115 Volt: Connect one hot wire (black or red)
to one of these screws (it doesn't matter
which one). Connect the white (neutral) wire
to the other screw. Cap any remaining
black or red wires.
Clamp the power cable to prevent strain
on the terminal screws.
Connect the green (or bare copper) ground wire
to the green ground screw.
Figure 6B:Wiring connections to Pressure Switch. Follow
instructions for your type of switch and your line voltage.
Hazardous voltage. Can shock, burn, or kill.
Connect ground wire before connecting power supply
wires. Use the wire size (including the ground wire) speci-
fied in the wiring chart. If possible, connect the pump to a
separate branch circuit with no other appliances on it.
Explosion hazard. Do not ground to a gas sup-
ply line.
1-800-468-7867 / 1-800-546-7867
7