English
complete with a pre-mounted Shuko plug. Before connecting up, make
sure that the rated voltage of the appliance (230V) corresponds with the
mains voltage, and also check that the wall socket is properly earthed in
compliance with current regulations and that it is capable of delivering
the rated current required to operate the chosen model at full power. This
socket must be controlled by a double-pole switch that turns the radiator
on and off. In case of damage, replace the power cable of these radia-
tors. Repair operations must be carried out only by the manufacturer.
8. Cautions
During standard operation, the radiator surfaces become very hot.
It is normal for the bottom pipes not to heat up.
Only fabrics that have been washed in water can be dried on the Electric
Radiators.
The resistors of electric radiators cannot work without filling fluid; it is
therefore prohibited to open the connections on the radiator.
In the event of accidental overheating and/or improper use, the resistor
circuit may be cut out. In this event the resistor can no longer be used,
and must be replaced.
The towel rail must be positioned in such a way to allow the electronic
control to detect the room temperature in the best possible way, far from
external heat sources.
9. Replacing the resistor
Should it be necessary to replace the resistor, this must be done exclu-
sively by the manufacturer, by an authorised person, or by a person with
suitable qualifications, so as to avoid any risks.
10. Thermostat instructions
Display LCD
[Crono] Key
[Mode] Key
[Eco] Key
Display LCD
ECO function and starting
adaptive power
Crono mode
selected program
Setted hour or
temperature
Crono mode daily program
a. ON / STAND BY
Press the [On / Stand by] key to turn on the unit or program the "Stand-
by" mode. When the thermostat is active, the mode and temperature are
displayed. During "Stand-by" the display shows the current time and the
day of the week.
NOTE: When the device enters "Stand-by" mode, 2 sounds of duration
are output halfa second. When the device is switched on, it emits a sound
lasting one second.
b. COMFORT e NIGHT MODES
Two different levels of the temperature can be set:
-"COMFORT" temperature: It is the temperature used for "Chrono", "Fil
pilot" and "Comfort" modes.
-"NIGHT" temperature: It is the temperature used for the "Night" and
"Chrono" modes.
The desired temperature can be set pressing the [+] or [-] buttons. The
range of configurable temperature is 7°C - 32°C.
IMPORTANT!
The temperature of "Night" mode must be below to the "Comfort" mode
temperature. For this reason, the "Night" mode temperature can be set to
a value between 7°C and the "Comfort" mode temperature.
The "Comfort" temperature can be set throughout the range of 7°C to
32°C. If "Comfort" temperature is set below "Night", the latter is set equal
to the first.
c. Thermostat functions and modes
Press [Mode] key to move between the permitted operating modes
.
An icon on the display indicates the current operating mode (see table).
Fil Pilote
Lcd display
Mode Fil Pilote (not present)
Comfort Mode
It is the normal use of the radiator to maintain the room temperature
[+] Key
to the set value.
- Press the [mode] button until the corresponding icon appears on
[-] Key
the dispaly.
[On/Stand-by] Key
- Select the desired temperature with the [+] and [-] buttons.
Night Mode
By selecting this mode, the unit will keep the room at the set night
temperature. The desired night temperature setting is as follows:
-Press the [mode] button until the corresponding icon appears on the
Mode:
- Stand-By
display.
- Crono
-Select the night level temperature using the [+] and [-] buttons.
- Antifreeze
- Night
- Comfort
Antifreeze Mode
- Fil Pilote
-Selecting this mode will set the room temperature to 7°C.
-Press the [mode] button until the corresponding icon appears on the
Keys lock icon
display.
Open window
relevation icon
Chrono Mode
Current week
In this mode, the ambient temperature is maintained at the comfort
day
level or at the Nightly level according to time slots programmed as
desired by the user.
-Press the [mode] button until the corresponding icon appears on the
- 10 -
Comfort
Night Antifreeze ECO Chrono
Adaptive starting
Open window
Key lock
control
system
Cod. 1910000000078 - nv00