Technical Specifications - Cordivari Ardesia Instrucciones De Uso

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Operating Instructions -
1. General information
These instructions are in connection to the following Cordivari electric
radiators and in particular to the models:
Height
Width
[mm]
[mm]
ARDESIA ELECTRIC 3 COLUMNS
338
384
568
614
600
706
798
982
1120

2. Technical specifications

Cordivari electric radiators with digital room thermostat:
• Class I Insulation
• Protection: IP 44
• Operating thermostat inside resistor calibrated to 90 - 100 °C
• Safety thermo fuses calibrated to 152° C
These radiators are filled in the factory with a clearly specified amount of
special fluid ensuring heat transmission.
If any of these fluids leaks out, the radiator must be restored to optimum
working conditions by the manufacturer, a person delegated by the man-
ufacturer or a person with suitable qualifications, to ensure that proper
operating and safety conditions are restored.
3. Information for the user
To clean painted radiators, use only a non-abrasive cloth dampened with
water.
To clean the stainless steel radiators you can use a non-abrasive cloth
dampened with water and methyl alcohol diluted to 50%. Do not use de-
tergents or aggressive substances. Avoid any acidic or basic solutions,
industrial chemicals or other substances, corrosive or abrasive substanc-
es (bleach, ammonia, soda...). Do not use abrasive sponges or cloths.
4. Information for the installer
The product purchased is subject to the general rules of warranty so as writ-
ten in the official Cordivari Catalogue in force. The warranty starts from the
date of delivery and is void if the indication of the production lot is tampered
with and / or removed. The warranty shall be effective after examination of
the defects and their relevant causes. The material to be replaced or re-
paired must be delivered at the retailer warehouse. The obligation to provide
the warranty is subject to the conditions and requirements set out below.
The radiator has not been damaged during shipping, handling or installation
and any repairs and / or modifications have been carried out by a third party,
if not expressively authorized. The material has been stored in good condi-
tion and protected from the weather before being installed. The installation of
this product should be performed by qualified personnel and in accordance
with these instructions and all system and safety rules both national and
local. Do not place the radiators in rooms with the presence of chlorine va-
pours or corrosive fumes such as swimming pools, saunas, spa tubs.
5. Instructions for installation in bathrooms
Since Cordivari electrical radiators are equipped with a resistor with
Cod. 1910000000078 - nv00
Ardesia Electric Radiators with digital thermostat
Electric
ELEMENTS
Power [W]
7
400
8
500
12
750
13
900
15
1000
17
1200
21
1500
24
2000
CLASS 1 insulation and have a minimum protection degree of IP44, they
can be fitted in Zone 2 danger areas (see figure) provided that the power
supply line is protected by a differential circuit breaker with Idn ≤ 30 mA
according to CEI 64-8 standard.
In any case the power socket and differential circuit breaker must be
located in zone 3, and none of the electrical controls must be reached by
a person during bath or shower.
Install the radiator in such a way that the minimum distance between
the floor and the thermostat is 250 mm and make sure that there are
no obstacles within a minimum distance of 100 mm from the appliance.
AREA 1
AREA 2
AREA 3
Position the radiator so as to comply with the following minimum
distances:
6. Wall mounting
The electric radiators must be mounted on the wall following the instruc-
tions provided in the packaging of fastening supports.
Fastening systems (screws + dowels) are suitable for compact walls or
walls in hollow bricks. For different material walls it is the installer respon-
sibility to adopt the suitable fastening systems.
When the radiator is in the proper position, the resistor is located at the
bottom right.
The radiator must absolutely never be installed with the resistor aimed
from top to bottom or in any direction other than pointing from the bottom
to the top, as the heating element in the resistor itself would be irreversi-
bly damaged during operation.
Never position the radiator in front of the power socket.
Make sure that the resistor never operates unless it is fully submerged.
7. Connecting up
All models of Cordivari electric radiators are fitted with a power cable
- 9 -
English
AREAS 0

Publicidad

Tabla de contenido
loading

Tabla de contenido