23 9. Technical Data; 23 9.1 Exhaust Gas Measurement; 24 9.3 Dimensions And Weights; Temperature - Bosch BEA 750 Manual Original

Análisis de emisiones
Ocultar thumbs Ver también para BEA 750:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 75
en
32 | BEA 750 | Technical Data
9.
Technical Data
9.1
Exhaust gas measurement
component
Measuring range
CO
0,000.. 10,00 %vol
CO
0,00.. 18,00 %vol
2
HC
0.. 9999 ppm vol
O
0,00.. 22,00 %vol
2
Lambda
0,500.. 9,999
CO
0,00.. 10,00 %vol
vrai
(not Germany)
NO
0.. 5000 ppm vol
Accuracy class 1 and class 0 as per OIML R99 Ed. 2008
9.2
Specifications
Property
Rated voltage U
AC
Rated power P
Frequency F
Type of protection
9.3
Dimensions and weights
Property
Dimensions W x H x T:
Weight (without accessories)
|
1 689 989 339
2017-12-12
9.4
Property
Function
Resolution
Storage and transportation
0,001 %vol
0,01 %vol
9.4.1
1 ppm vol
0,01 %vol
Property
0,001
Storage and transportation
0,01 %vol
Operation (at 25 °C and 24 h)
Measurement accuracy
1 ppm vol
9.4.2
Property
Storage and transportation
Value / range
Function
Measurement accuracy
100 V – 240 V
90 W
50 Hz / 60 Hz
9.5
IP 20
Class
Mechanical
Electromagnetic
Value / range
9.6
570 x 270 x 320 mm
22.4 x 10.6 x 12.6 inch
14 kg
Property
31 lb
Workplace emission sound pressure
level as per EN ISO 11204
Sound power level as per
DIN EN ISO 3744
9.7
Wireless link
Bluetooth

Temperature

Air pressure
Humidity
MID environment categories
Noise emissions
RED (Radio Equipment Directive)
Frequency band
Maximum radiated
transmitter power
output
2,4 GHz
20 dBm
Value / range
5 °C – 40 °C
41 °F – 104 °F
0 °C - 50 °C
32 °F - 122 °F
Value / range
700 hPa – 1060 hPa
700 hPa – 1060 hPa
700 hPa – 1060 hPa
Value / range
30 % – 60 %
20 % - 80 %
30 % – 60 %
Level
M1
E2
Value / range
< 70 dB(A)
< 72 dB(A)
Robert Bosch GmbH

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Bea 065

Tabla de contenido