Converting To Lp Vapor; Coverting To Lp Vapor; Installing & Connecting Gas Lines - Generac CorePower 5837 Lineamientos De Instalación

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

CONVERTING TO LP VAPOR

1. Remove the generator enclosure roof by turning the four
quarter turn latches on the roof top. Push down slightly on the
latch then turn 90 degrees to release. The latch should pop up
as shown.
\2. Remove the two side panels of the enclosure by lifting the
panels straight up until they are clear.
3. Carefully place the roof and side panels to one side.
4. Locate the fuel throttle assembly mounted to the engine
intake.
Remove Clamp
and Hose
6
5. To change the fuel selection, remove the hose clamp and
hose from the throttle assembly.
6. Remove the Natural Gas (Larger ID) fuel jet from the fuel inlet.
7. Obtain the fuel jet for Propane (Smaller ID that has been
supplied loose with the owners manual).
8. Verify that the O-ring, supplied loose with the owners manual
is installed, into the groove of the fuel jet.
9. Insert the Propane fuel jet into the end of the fuel inlet.
10. Reinstall the hose and clamp onto the fuel inlet and secure.
11. Verify the hose has not been kinked in any way.
Throttle
Assembly
Fuel Jet
12. The generator is now ready to run on LP Vapor fuel.
INSTALLING & CONNECTING GAS LINES
1. Both natural gas and LP Vapor are highly volatile substances,
so strict adherence to all safety procedures, codes, standards
and regulations is essential.
Gas line connections should be made by a certified plumber
familiar with local codes. Always use AGA-approved gas pipe
and a quality pipe sealant or joint compound.
Verify the capacity of the natural gas meter or the LP tank in
regards to providing sufficient fuel for both the generator and
other operating appliances.
Fuel Inlet
O-Ring (installed)
Hose Clamp
Regulator
Hose

Publicidad