Technical Specifications - Nordcap MORETTI LINK Manual Del Usuario

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

1

TECHNICAL SPECIFICATIONS

1.1
DESCRIPTION OF THE APPLIANCE
The appliance consists of two heating modules: the lower one is
identified as "DECK 1", the upper one as "DECK 2".
It has electronic temperature regulation, it is equipped with two
thermocouples (one for each module ) for greater precision in
maintaining the temperature, with swing doors hinged at the
bottom.
Internally each module has a heating surface and walls in
aluminized sheet.
1.2
APPLIED DIRECTIVES
This appliance conforms to the following Directives:
Low Voltage Directive 2014/35/EU
Electromagnetic Compatibility Directive 2014/30/EU
1.3
WORKPLACES
The appliance is programmed by the operator using the control
switchboards located on the front and it must be attended to while
in operation.
The doors giving access to the appliances are located at the front
of the appliance.
1.4
MODELS
The foreseen models are
LINK
1.5
TECHNICAL DATA (See TAB. 1)
1.6
WORKING DIMENSIONS AND WEIGHTS (See
Fig. 1)
1.7
IDENTIFICATION
For any communicating with the manufacturer or with the service
centres, always give the appliance's SERIAL NUMBER, which
can be found on the rating plate, fixed in the position indicated in
Fig. 2.
1.8
LABELLING
The appliance is provided with caution warning labels at the
points shown in Fig. 3.
CAUTION!
On the equipment surface there is a burn
hazard due to the presence of high temperature elements. For any
type of intervention or operation, wait for the appliance to cool to
room temperature and always use suitable protective equipment
(gloves, goggles, etc.)
CAUTION!
Presence of dangerous voltage. Before
performing any maintenance operations, turn off the power supply
by turning off the switches installed outside the appliance and wait
for the appliance to drop to room temperature. Always use suitable
protective devices (gloves, goggles, etc.).
1.9
NOISE
This appliance is a technical working means which normally, at
the operator's position, does not exceed a noise emissions
threshold of 70 dB (A).
2
INSTALLATION
2.1
TRANSPORT
The appliance is normally shipped on a wooden pallet with ground
transportation vehicles (Fig. 4), protected by a plastic film or
cardboard box.
2.2
SCARICO
NOTE:
Upon delivery, it is recommended to check the
status and quality of the appliance.
Lift the appliance by using only and exclusively the points
indicated in Fig. 5.
2.3
ENVIRONMENTAL SPECIFICATIONS
For the good operation of the appliance, it is advisable that the
environmental values have the following limits:
Working temperature: +5 °C to +40 °C
Relative humidity: 15% to 95%
2.4
POSITIONING, ASSEMBLING AND
MAINTENANCE AREAS
CAUTION!
installing the following provisions must be met:
- Laws and Standards in force regarding the installation of
electrical appliances.
- Directives and indications issued by the electricity supply
network.
- Local building and fire-prevention laws.
- Accident prevention regulations.
- Indications in force issued by local state Electric Quality
Assurance Corporation.
Remove the protective film from the external panels of the
appliance by slowly peeling it off to remove the adhesive.
If this does not happen, remove the glue residues perfectly using
kerosene or gasoline.
The appliance is supplied with support feet.
Install the appliance on a suitable and stable support.
In addition, the appliance must be positioned in a well-ventilated
place at a minimum distance of 10 cm from the left, right and
bottom side wall (Fig. 6).
Keep in mind that to carry out some cleaning/maintenance
operations these distances must be greater than those shown,
therefore the possibility of being able to move the appliance in
order to carry them out must be considered.
CAUTION!
When using, be careful not to obstruct the
area space determined by the thickness of the support feet.
2.5
CONNECTIONS
2.5.1
ELECTRICAL CONNECTION
CAUTION!
The electrical connection must only be
carried out exclusively by qualified personnel, in compliance
with current local state Electric Quality Assurance
Corporation requirements.
Before starting the connection procedure, check that the
grounding system is provided in accordance with European
EN Standards.
Before starting the connection procedure check that the main
switch of the plant to which is connected the appliance is in
the "off" position.
La targhetta matricola contiene tutti i dati necessari per un
corretto collegamento.
2.5.1.1 ELECTRICAL
APPLIANCE
CAUTION!
It is necessary to install a bipolar main
switch with fuses or an automatic switch suitable for the
values shown on the plate, which allows disconnecting the
appliance from the network and which allows complete
disconnection in the conditions of overvoltage category III.
NOTE:
The device selected should be in the immediate
vicinity of the appliance and within easy access.
UK/2
During positioning, assembling and
CONNECTION