INSTALLATION INSTRUCTIONS
12
"
(305mm)
1/2
"
(12.7 mm)
44
Rear
View
designation, make sure that the handle stem flats locating mark is facing upwards
and away (opposite direction) from the inlet.
Outlet 2
Outlet 1
Outlet 3
Inlet
Assembly of Outlet Connections
There are 3 outlets of the transfer valve, providing 3 separate, discrete functions.
Suggested outlet designations are as follows:
• Outlet #1: Handshower
• Outlet #2: Showerhead
• Outlet #3: Tub Spout, Additional Showerhead, or Handshower
NOTE: Do not block any outlet. If any outlets are not to be used (i.e. tub spout), the outlet should
be plumbed into the line of one of the other outlets. This valve is not intended to be used as
a shut-off valve. Damage to the shower system may result if the valve is used as a shut-off
valve. To prevent the potential of cross flow, check valves must be integral to the supply
valve or installed in both hot and cold water supply lines.
Rough-in Body Casting
1. The distance from the supply valve center to the center of the transfer valve must be a minimum of 12"
(305mm) to assure proper clearance of the transfer valve escutcheon and supply valve escutcheon.
2. In the finished wall, make a minimum hole of 2-1/2" (64mm) diameter for the transfer valve installation.
FINISHED
3. The plaster ground is used as a guide to help install the valve at the proper depth within the wall. The
WALL
plaster ground should be flush with the finished wall once the transfer valve is installed. The inlet of the
transfer valve may not be aligned with the outlet of the shower valve. For example, the transfer valve
installed with Posi-Temp has an offset as shown in the Figure at left.
56
" TYP
Cap
Shower Port
" TYP
FLOOR
Hot
5. With the valve castings "IN" port facing
directly down, connect the outlet of the
main supply valve to the inlet of the
transfer valve using a 1/2" copper water
tube. If the supply valve has 2 outlets, one
of these outlets must be plugged.
CAUTION:
For all installations, the cartridge must
be removed from the valve body before
heating the valve. Failure to do so will
result in cartridge damage. Please refer
to the instructions 'Removing Cartridge for
CC Connection/Servicing.'
Handle Stem Position for Handle
Adapter/Handle Assembly
For correct handle position/outlet flow
Valve
Valve
Front
Rear
Cold
Valve Housing
Cartridge
Removing Cartridge for CC Connection/Servicing
1. Remove plaster ground but do not discard.
2. Using an adjustable wrench on the flats, remove the externally threaded top
plate by turning it counterclockwise (CCW).
3. Grasp the cartridge by the stem with pliers and pull the cartridge straight out.
Stem Flats
Locating
Mark
Figure 3
Installing Cartridge Into Transfer Valve Body
1. Place the cartridge into the transfer valve body, positioning the 2 locating
pins on the bottom of the cartridge (Figure 1) into the 2 locating holes in the
transfer valve body (Figure 2). Assure that the stem flats locating mark is
facing upwards and away from the inlet (Figure 3).
4. The Positemp Valve can be
connected to the Diverter Valve
in the configuration shown at left.
The top port (Shower Port) on the
Positemp Valve will need to be
capped.
Handle Stem Bushing
Stem
Plaster Ground
Top Plate
Cartridge
Figure 1
Locating Pins
Figure 2
Valve Housing
Locating Holes
2