Trouble Shooting - Interpump Group QUIKY TURBO 11.50 Instrucciones Para El Uso

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 54
TROUBLE
The pump is running but
maximum pressure is
not obtained
Fluctuating pressure
Pressure decreases
Excessive noise
Presence of water in oil
Water dripping from under pump
Oil leakage
The motor hums but does not run
when turned on
The motor does not start when
switched on
The motor stops

12 - TROUBLE SHOOTING

(FOR QUALIFIED PERSONNEL)
CAUSE
Air sucked into pump
Worn or dirty valves
Unloader packings worn
Nozzle worn or incorrect
Piston packings worn
Dirty filter
Damaged, dirty or clogged valves
Air is being sucked
Worn packings
Dirty filter
Worn nozzle
Dirty or stuck valves
Bypass packings worn
Piston packing worn
Dirty filter
Air suction
Damaged, dirty or stuck valves
Worn bearings
Water temperature too high
Dirty filter
Piston packings and oil seals wor n
High air humidity
Piston packings worn
Packing o-rings worn
Oil seals worn
System voltage is lower to the
minimum advised
The pump is stuck or fr ozen
Extension cord incorrect
The plug is not well connected
No power supply
The thermal protector has tripped
due to overheating
19
REMEDY
Check suction hose and fittings
Clean or replace
Check and/or replace
Check and/or replace
Check and/or replace
Check and/or clean
Check, clean and/or replace
Check suction hose and fittings
Check and/or replace
Check and/or clean
Substitute nozzle
Check, clean and/or replace
Check and/or replace
Check and/or replace
Check and/or clean
Check suction hose and fittings
Check, clean and/or replace
Check and/or replace
Lower water temperature to
under 60°C
Check and/or clean
Check and/or replace
Change oil twice as frequently
as that advised
Check packings
Replace O.R.
Replace oil seal
Check that your power source
is adequate
See page 16
Check the extension cord
table on page 11
Check plug, cord and switch
Check that the mains voltage cor-
responds to the specifications:
TURBO 8/70 - 11/50:
switch off the motor and let it cool
a few minutes
TURBO 15 - 19 - 21 - 11/70 - 8/90
- 10/100: wait a few minutes
before turning on the unit again