MODEL
Flow rate
Equivalent
washing impact
E.W. MPa
with rotating
E.W. bar
nozzle jet
E.W. P .S.I.
Working pressure
Overpressure
peak limit
Recoil thrust of jet
Singlephase
motor power
Motor protection
Motor protection grade
*
Noise level
*
Lance vibration
Max. water inlet
temp
Max suction depth
High pressure hose
Mass
Dimensions
*
(Reference Standard EN60335-2-79)
2 - TECHNICAL DATA
TURBO
TURBO
11-50
8-70
11 l/min.
8 l/min.
2.9 G.P.M.
2.1 G.P.M.
E.W. bar / MPa / P.S.I.: specific jet pressure in bar / MPa / P.S.I.
14.5
10
100
145
1450
2100
5
7
MPa
50
70
bar
1000
725
P.S.I.
8
10
MPa
80
100
bar
1160
1450
P.S.I.
< 20
20
N
2
Kg
< 2
1,68 1,64
1,68 1,64
kW.
240
230
230
V.
50
50
Hz.
10,5
8
8,2
A.
Fixed nozzle A(8) than 2,5 - Rotating nozzle A(8) 3 (uncertainly 0,5)
2
m/sec
60
60
°C
140
140
°F
1
1
m
3,3
3,3
ft
8 m
Thermoplastic material reinforced with nylon braid inter nal diameter 5/16"
Maximum working pressure 130 bar /13 MPa / 1885 P.S.I.
26 ft
18,5
18,5
Kg
40,8
40,8
lbs
mm
inches
TURBO
TURBO
15
19
8 l/min.
8 l/min.
2.1 G.P.M.
2.1 G.P.M.
12
13
120
130
1750
1885
5.5
6
55
60
800
870
8.5
9
85
90
1235
1300
< 20
< 20
< 2
< 2
1,36
1,40
240
100
100
50
60
15
15
8
Current thermal overload
IPX5
Lp dB(A) 76 (uncertainly 1,5) - Lw dB(A) 90
60
60
140
140
1
1
3,3
3,3
18,6
19,4
41
42,8
360x240x235 (h)
14,2x9,4x9,2 (h)
6
TURBO
TURBO
TURBO
21
11-70
8 l/min.
11 l/min.
8 l/min.
2.1 G.P.M.
2.9 G.P.M.
2.1 G.P.M.
13.8
14,5
138
145
2000
2100
7
7
70
70
1000
1000
10
10
100
100
1450
1450
< 20
24
2,4
< 2
1,58
2,2
115
240
230
230
60
50
15
10,5
9,5
10,5
60
60
140
140
1
1
3,3
3,3
19,4
21,4
42,8
47,2
405x240x235 (h)
15,9x9,4x9,2 (h)
TURBO
8-90
10-100
10 l/min.
2.6 G.P.M.
16
17
160
170
2320
2465
9
10
90
100
1300
1450
12
13
120
130
1750
1885
20
27
2
2,7
2,2
2,65
240
230
50
50
12
9,5
60
60
140
140
1
1
3,3
3,3
22,3
23,5
49,2
51,8