EN – Installation instructions
The radiator may only be installed by a specialist.
Safety instructions
Read these instructions thoroughly prior to
►
installation/commissioning.
►
After installation, pass the instructions on
to the end user.
DANGER
Life-threatening situation!
Check the condition of the supply lines
►
(electricity, gas, water).
Do not drill into any lines.
►
WARNING
Risk of injury!
Take the weight of the radiator into ac-
►
count (see manufacturer's data).
At 25 kg and above work with lifting
►
equipment or several persons.
WARNING
Personal injury and material damage!
Check substrate for load-bearing capaci-
►
ty. Take the filled weight of the radiator
and possible additional loads into ac-
count (see manufacturer's data).
►
Check fasteners for applicability and tai-
lor them to the structural situation.
Take special requirements, e.g. for pu-
►
blic buildings (schools or the like), into
account.
Conditions of use
Observe operating conditions for water
►
heating installations according to local
regulations.
►
Maintain water quality according to local
regulations.
Observe usage limits in humid spaces ac-
►
cording to local regulations.
Use radiator only in closed heating sys-
►
tems.
Store and transport radiator only in the
►
protective packaging.
Complaint
Please contact the supplier.
►
Disposal
Packaging and any parts that are not need-
►
ed should be recycled or disposed of prop-
erly. Observe local regulations.
Technical features
Operating pressure: max. 10 bar
•
Test pressure: 1.3 x operating pressure
•
Flow temperature: hot water up to 100°C
•
(212°F)
Installation
Preparatory activities
Check fasteners for damage.
►
Note the number of mounting points (see
►
Fig. A).
Number determined and checked on
–
vertical coring lightweight brick T14.
Requirement
–
VDI 6036 permissible when complying
with Appendix D. If necessary, install
additional shift restraint (refer to manu-
facturer's documentation).
Note the position of mounting points (see
►
Fig. C).
When installing, only remove protective
►
packaging at the fastening and connection
points.
Assemble the radiators delivered in blocks
(see Fig. B)
Accessories per connection:
Item Group
1
Screw-in fitting M 27
2
Screw-in fitting with flange
3
Union nuts SW 30
4
Panel
Set individual blocks on a clean and level
►
base.
With an Allen key SW 12 screw the screw-in
►
fittings M 27 (1) on one of the blocks in and
tighten (tightening torque 40 Nm).
Put the screw-in fittings with flange (2) in
►
the union nuts SW 30 (3) and screw down
on the second block.
With an Allen key SW 12 tighten the screw-
►
in fittings with flange (2) (tightening torque
40 Nm).
class 2
according
Number
2
2
2
2
to
5